4.3
Tool Reels
4.3.1 Reel Lubrication
The tool reels are factory lubricated for life. No additional lubrication required.
4.3.2 Cable Inspection
The tool reel cables will need to be periodically check the cable for wear. If wear is
detected, the cable should be replaced immediately. If cable replacement is required,
the cable and its related parts (lock washer and nut) should be replaced along with it.
(See also maintenance schedule - sec. 4.9)
4.3.3 Tension Adjustment
Danger! - Never add / remove tension when the cable is extended from the reel. The
cable must always be fully wound on the reel.
Danger! - DO NOT allow cable to retract in an uncontrolled manner. Always guide cable
back to reel. Failure to do so can result in damage to reel or personal injury.
Tension adjustment procedure:
1. Hold shaft securely with wrench and remove 2 screws from hub.
2. Turn shaft clockwise / counter-clockwise to add / remove tension (one full turn at a
time).
3. When desired tension is achieved, replace the 2 screws.
4.3.4 Spring Replacement
Danger! - DO NOT attempt to remove spring motor from its canister. Doing so can result
in damage to reel or personal injury.
Spring motors are self-contained for safe and easy handling. If a spring motor
replacement is required, it should be replaced as a unit by ordering spring motor kit
which contains the spring motor, spool, shaft and bushings in a sealed canister.
4.3.5 Reel Sensors
Each tool reels are equipped with a proximity sensor that indicates when the tool is at
its home position or not. The home position is when the tool cable is fully retracted and