4.2.6.2 Wayside Compressor
The oil level should be checked regularly. The sight glass can be found in front of the
compressor base unit. If no oil is visible in the window, remove the oil plug from the
side of the compressor and add oil until it is visible in the window. The level should be
maintained as shown in the graphic to the right. Use full synthetic 30 weight air
compressor oil only. Do not overfill. (See also maintenance schedule - sec. 4.9)
4.2.7 Compressor Belts (Station Only)
Turn off the compressor to inspect the belts for damage, excessive wear, and correct
tension. Replace if necessary. Proper belt tension and pulley alignment must be
maintained for maximum drive efficiency and belt life. The correct tension exists if the
deflection of ½” occurs by placing 10 pounds force midway between the motor pulley
and the compressor flywheel. (See also maintenance schedule - sec. 4.9)
Warning! – make sure that power is disconnected from the equipment prior to belt
guard removal. Do not operate the compressor with the belt guard removed.