2.1.2.2 Power Supply
STATION
Voltage: 195-265 volts AC (Single Phase)
Max Power Consumption: 6600 watts
Frequency: 60 hertz
The unit can be plugged into any 230V 30A (NEMA 6-30) outlet. The electric
socket must be of the type 230V 30A correctly connected and protected by a
proper current-fault circuit breaker. The installation must comply with standard
regulations in activity inside the country to power mains supply.
*Electric wiring must be conforming to National Electrical Code NFPA 70 or NF C
15100 standards, or must comply with standard regulation in activity inside the country to
power mains supply. The presence of grounding (earth) wire and a frame with a proper
ground-fault protection breaker is mandatory.
WAYSIDE 120V
Voltage: 85-138 volts AC (Single Phase)
Max Power Consumption: 960 watts
Frequency: 50-60 hertz
The unit can be plugged into any 125V 15A (NEMA 5-15R) outlet. The electric
socket must be of the type NEMA 5-15R 3 hole outlet 125V 15A correctly
connected and protected by a proper current-fault circuit breaker. The
installation must comply with standard regulations in activity inside the country
to power mains supply.
*Electric wiring must be conforming to National Electrical Code NFPA 70 or NF C
15100 standards, or must comply with standard regulation in activity inside the country to
power mains supply. The presence of grounding (earth) wire and a frame with a proper
ground-fault protection breaker is mandatory.
2.1.2.3 Grounding
A grounding rod should be installed with all units mounted to the ground. The unit
should be grounded directly. No splices or connections are allowed in the ground wire
between the unit and the ground rod. The minimum grounding wire to run to the unit
should be 8 gauge.
It is vital to get a good, solid connection. A
void making 90° or
sharper turns with the ground wire. A lightning charge has difficulty making such a turn