CD3 Products Manual
CD3, General Benefit Corporation |
| 612.467.9441
Patent
Pending | Made in USA | © 2019
38
4.2.4 Air Filter
A dirty air filter will reduce the compressor’s performance and life, and will cause the
compressor to pump oil. To avoid any internal contamination of the compressor pump,
the filter should be replaced on a regular basis. Do not allow the filters to become filled
with dirt. (See also maintenance schedule - sec. 4.9)
Station
Wayside
4.2.5 Air Leaks
Check that all connections in the air system are tight on a regular basis. A small leak in
any of the hoses, transfer tubes, or pipe connections will substantially reduce the
performance of the air compressor. If you suspect a leak, spray a small amount of soapy
water around the areas with a spray bottle. If bubbles appear, reseal and retighten the
connection. Do not over-tighten. (See also maintenance schedule - sec. 4.9)
4.2.6 Compressor Oil
4.2.6.1 Station Compressor
The oil level should be checked regularly. The sight
glasses can be found in front of the compressor base
on the Station. The level should be maintained at
about ¼” above the center of the sight glass with 30-
weight quality non-detergent air compressor oil only.
Do not overfill. The original break-in oil should be
changed at 8 hours of operation. For operating
temperatures below 30 degrees Fahrenheit, use 10
weight air compressor oil. (See also maintenance
schedule - sec. 4.9)