13
care not to damage the mounting studs while placing the unit. The five studs should
be located in the open spaces just inside the major base frame beams.
3.
Install the mounting brackets as shown in the above diagram. Install and tighten the
hardware. Note: The mounting brackets may be studs in the concrete or threaded
inserts. Hardware to match either should be included in the mounting kit.
4.
Drive grounding rod into the ground and attach the ground wire. There is a small
hole on the side of the unit near the rear corner on the compressor side of the unit
for routing the grounding wire out. Route the wire through the hole and connect to
the grounding rod. The grounding rod preferred location is in a 24” radius of that
corner of the unit.
5.
Plug the unit into its power source (if applicable) and re-install the rear panels. The
station unit will plug into the electrical box from the concrete base where the
wayside units may plug into a 120V outlet in the same location or not at all
depending on the unit configuration. Re-install the rear panels and door in the
reverse order of disassembly.
2.1.1.2 Installation Procedure (Outpost)
1.
Remove the rear door by simply swinging it all the way open and lifting up and the
hinges will separate. Removing the door will allow the ability to manipulate the unit
position without the door swinging around.
2.
Place the unit on the concrete mounting base by lifting it over the mounting studs
and locating it to align with the mount holes. Take care not to damage the mounting
studs while placing the unit. The four studs should locate in the corresponding base
frame holes.
3.
Install the mounting hardware and tighten. Note: The mounting may be studs in
the concrete or threaded inserts. Hardware to match either should be included in
the mounting kit. Re-install the door in the reverse order it was removed.
2.1.2 Electrical Install (Station, Wayside 120V)
2.1.2.1 Safety Warnings
1.
Improper connection of the equipment-grounding conductor can result in a risk of
electric shock.
2.
Check with a qualified electrician or service person as to whether the outlet is
grounded.
3.
Do not modify the plug provided with the appliance – if it will not fit the outlet, have
a proper outlet installed by a qualified electrician.
4.
Make sure that the appliance is connected to an outlet having the same
configuration as the plug.
5.
No adapter should be used with this appliance.
6.
No extension cord should be used with this appliance.