| P
age 36 | SEABOB Operation Manual |
5
| P
age 37 | SEABOB Operation Manual |
5
|
Online Version
|
|
Online Version
|
5.3.7 Charge mode
The charger is connected to the device and is supplying
the charging voltage. Before charging begins, an ac-
cumulator / charge diagnostic check (system check) is
performed. Charging is activated once the diagnostic
check has been completed successfully. It is not possible
to switch on the motor. The charge display showing the
accumulator symbol will appear in the display (see Chap-
ter 5.3.8 "Charge display").
The system can only be switched from another mode to
Charge mode using a connected and active charger.
Note:
If the charger is disconnected from the device,
thereby interrupting the charging voltage, the SEABOB
switches off after 5 seconds (system check) and switches
to Off mode (if programmed to partial charging) or to
Sleep mode (if programmed to full charging).
5.3.8 Charge display
After the charger is connected to the SEABOB and then to a
power source, the system first performs a system check and
then automatically switches to Charge mode. The charge
display appears. It is not possible to switch on the motor.
1. The charge state is shown by individual bars in the
accumulator symbol on the right-hand side of the
display (1 bar = 10 % charge state). The number of
bars indicates the charge state. When all bars are
shown in the accumulator symbol, the SEABOB is fully
charged.
2. The numerical display of the charge state (in % of full
charge state) is shown above the accumulator sym-
bol. The accumulator temperature (in°C) is displayed
under the accumulator symbol.
3. The current water temperature (in °C) is shown at the
top left of the display.
4. Tap the green button to select partial charging of the
SEABOB for air transport / storage. A partially filled
charge symbol will appear in the centre of the display
with an arrow to indicate partial charging ("charge
50 %").
5. Tap the red button to select full charging of the
SEABOB for operation. A completely filled charge
symbol will appear in the centre of the display with
an arrow to indicate full charging ("charge 100 %").
Note:
When an active charger is connected, program-
ming is preset to full charging (for operation).
Water
temperature
Charge symbol
(selected charging process)
Accumulator temperature (in°C)
Accumulator
charge state
(in % of full
charge state)
6. If programmed to partial charging for air transport /
storage, an aircraft symbol will appear when the cor-
rect partial charge state has been reached.
7. If programmed to full charging, all bars are displayed
in the accumulator symbol. The SEABOB is fully
charged and ready for operation.
8. To save energy and to reduce maintenance charging,
the display turns itself off automatically 10 minutes
after charging is completed (“complete”). By pressing
any button, the display can be switched on again (for
another 10 minutes).
9. If, when programmed to partial charging, the charger
is disconnected from the device when the aircraft
symbol is displayed, the system switches to Off mode
and switches off for transport, in particular air trans-
port, or storage.
10. If the charger is disconnected from the device when
programmed to full charging and the SEABOB is fully
charged, the system switches off to Sleep mode and
is ready for operation.
5.3.9 Displaying serial numbers
1. Switch on the SEABOB. The information display ap-
pears in the display.
2. Tap the button combination silver – blue – red in
quick sequence.
3. Enter your Owner-PIN and confirm your entry by
pushing the Trigger (see Chapter 5.3.10 "Entering
PIN"). The menu containing various menu items (up-
per menu level) will appear.
4. Switch between the menu items (upper menu level)
with the green or red button until the system data
("system data") are displayed in white. Select it by
pushing the Trigger.
5. The serial numbers of the SEABOB (the first letter is
an "S") and accumulators (the first letter is an "A")
as well as the software versions, can be displayed by
scrolling with the red button.
6. Push the Trigger against the Controlgrip to return to
the upper menu level.
7. To exit the upper menu level, switch between the
menu items with the green or red button until the
menu item to exit the menu appears ("exit"). Push
the Trigger to return to the information display.
Starting full charging for
operation
Partial charging for air trans-
port / storage complete
Full charging for operation
complete
Starting partial charging for air
transport / storage
SEABOB serial numbers
Содержание seabob f5 S
Страница 1: ...Online Version English User manual Online Version...