6921413
10
TROUBLESHOOTING
SSL
SSR
CL2
OP2
OPCK
1
CLC
K
TP
OPCK
2
CL
OP
CL1
OP1
FD
CC0352.eps
3.3-2
Clamp Circuit Test
(Continued)
5
Release the lever and watch the pressure gauge(s):
• If the pressure drop is
less
than 150 psi (10 bar) initially
and additional drop does not exceed 25 psi (1.7 bar) per
minute, the problem is not hydraulic. Refer to Section 3.3.
• If the pressure drop is
more
than 150 psi (10 bar) initially
and additional drop exceeds 25 psi (1.7 bar) per minute,
the CLAMP check valve cartridges in the revolving
connection may be faulty. Replace the cartridges.
6
Close the arms fully and hold the lever in the CLAMP
position for a few seconds. If the pressure still drops as
before, the cylinders are faulty and must be serviced. Refer
to Section 4.9.
End Block
Body
TP, Test Port
CLAMP Check
Cartridge
OPCK1, Cylinder
OPEN Check
Cartridge
OPCK2, Cylinder
OPEN Check
Cartridge
Flow Divider
Cartridge
CLAMP Circuit
Supply Hoses
CLAMP Circuit
Supply Hoses
Front View
(Revolving Connection with Sideshift shown)
Side View