From the mass display, press the  CAL/MENU key repeatedly until 

"intFACE"

 is displayed. Press the 

O/T

 key when 

"intFACE"

 is 

displayed, then press the  CAL/MENU key repeatedly until 

"iF:USEr"

 is 

displayed. To enter the user communication format menu, press the 

O/T

 key when 

"iF:USEr"

 is displayed. Baud rate, parity (and bit 

length), stop bit, delimiter, data format, and handshake can be set 
individually in the user format. 

 

Operate the keys according to the following descriptions and perform each 
setting. (**** is the current setting.) 

 

 

iF :USEr 

io.b:**** 

b- 300 

 

Sets the baud rate to 300 bps 

 

 
 

 

 

b- 600 

 

Sets the baud rate to 600 bps 

 
 

 

 

b-1200 

 

Sets the baud rate to 1200 bps 

 

 
 

 

 

b-2400 

 

Sets the baud rate to 2400 bps 

 
 

 

 

b-4800 

 

Sets the baud rate to 4800 bps 

 

 
 

 

 

b-9600 

 

Sets the baud rate to 9600 bps 

 

 
 

 

 

b-19.2k 

 

Sets the baud rate to 19.2k bps 

 

 
 

 

 

b-38.4k 

 

Sets the baud rate to 38.4k bps 

 

 
 

 

io.d:**** 

d-CR 

 

Sets the delimiter to C/R 

 

 
 

 

 

d-LF 

 

Sets the delimiter to L/F 

 

 
 

 

 

d-CrLF 

 

Sets the delimiter to C/R+L/F 

 

 
 

 

 

d-Cn 

 

Sets the delimiter to comma 

 

 
 

 

 

d-win 

 

Sets the delimiter to 

Windows

 Direct Format 

 

Содержание CAW Series

Страница 1: ...hock never disassemble the AC adapter The AC adapter is designed for indoor use Do not use the adapter in exterior environments or where it may be splashed by water Ensure that the power supply voltag...

Страница 2: ...low for a great variety of applications when used in conjunction with the peripheral units described in this manual The CAW CAX series of balances incorporates clock functions a built in motor driven...

Страница 3: ...EXTERNAL WEIGHT 23 7 3 SPAN CHECK USING THE BUILT IN WEIGHT 24 7 4 SPAN CHECK USING AN EXTERNAL WEIGHT 25 8 ZERO TRACKING 26 9 STABILITY DETECTION BAND 26 10 REGISTRATION RELEASE AND SELECTION OF MEAS...

Страница 4: ...D SPECIFIC GRAVITY MEASUREMENT 39 24 SINKER VOLUME FOR LIQUID SPECIFIC GRAVITY MEASUREMENT 40 25 DATE CAW CAX SERIES ONLY 40 26 TIME CAW CAX SERIES ONLY 41 27 PRINTING THE DATE TIME CAW CAX SERIES ONL...

Страница 5: ...depicted below Verify that all of the items are included in the shipping carton Name of Each Part 1 Main Balance Body 2 Pan 3 Pan Supporter 4 Anti draft Ring 5 Level 6 Leveling Screw 7 Glass Doors 8...

Страница 6: ...d Weighing symbol Indicates that Add Load Weighing is ON for the application measurement function Communicati on symbol Illuminates during communication to external equipment through the RS 232C or DA...

Страница 7: ...he setting menus when piece counting or units are displayed Moves to the next Menu Map item Tares the balance Displays zero 5 Selects and sets the currently displayed Menu Map item Changes the unit se...

Страница 8: ...ASE AND SELECTION OF MEASUREMENT UNITs 3 When the unit is set to 10d the resolution of the minimum display is decreased by one decimal place 4 Applicable to CAW CAX Series balances only 5 TARE may be...

Страница 9: ...pan in this order 2 Level the balance by turning the leveling screws to bring the bubble of the level indicator into the red circle 3 Verify that the pan is empty and connect the AC adaptor to the ou...

Страница 10: ...t the AC adapter from the outlet if the balance will not be used for a period of one month or longer 4 PRECAUTIONS Observe the following precautions Note Do not insert metal tools inside the balance h...

Страница 11: ...bility symbol to illuminate then press the O T key 2 Verify that 0 is displayed 3 Add the sample and read the display after the stability symbol appears 6 MENU SELECTION This balance is designed to en...

Страница 12: ...easurement mode SAmPLE Sets the Sample Pouring mode Hi Stb Sets the High Stability mode FUnC SEL Enters the next menu level application measurement and individual setting modes F See Section 6 1 FunC...

Страница 13: ...in abbreviation Indicates that automatic span Indicates that the GLP calibration is ON corresponding output is ON S t b 1 t Measuring mode Stability detection band Zero tracking Standard St 0 1mg b1 O...

Страница 14: ...the external weight i CAL Starts span calibration using the built in weight CAW CAX series only i tESt Starts span check using the built in weight CAW CAX series only trC on trC on Sets Zero tracking...

Страница 15: ...etter stability at zero point set the zero tracking trC on and trC oF to trC on To observe the variation of the mass amount when a liquid or powder is slowly injected set zero tracking to trC oF The s...

Страница 16: ...span calibration with the external weight E tEST Sets the span check with the external weight i CAL Sets the span calibration with the built in weight CAW CAX series only i tESt Sets the span check wi...

Страница 17: ...ACAL on ACAL on Sets automatic span calibration to ON CAW series only ACAL oF Sets automatic span calibration to OFF CAW series only A B Press the O T key Press the POWER BRK key Press the CAL MENU k...

Страница 18: ...Enters the next menu level Clock CAL automatic span calibration time setting mode CAW series only F See Section 22 Clock CAL STARTING TIME LSG SEt Enters the next menu level setting of the solvent sp...

Страница 19: ...ection 26 TIME tm AdJ Enters the next menu level time setting mode CAW CAX series only F See Section 26 TIME Prtdt on Prdt on Sets Date and time PRINT ON CAW CAX series only Prdt oF Sets Date and time...

Страница 20: ...th stop bit delimiter and data format all at the same time A user format is provided in addition to the preset formats The user can edit the communication parameters individually in the user format In...

Страница 21: ...rdware C R None 8 1 UF2 iF F3 Mettler 2400 Hardware C R L F Even number 7 1 UF3 iF F4 Sartorius 1200 Hardware C R L F Odd number 7 1 UF4 iF win Windows Direct 300 Software win None 8 1 UF1 iF US Er Us...

Страница 22: ...m 0 0001g U mg Miligram 0 1mg U Percentage U PCS Number of pieces e U ct Carat 0 001ct U mom Momme 0 00005mom U d Solid specific gravity U d Liquid specific gravity U Lb Pound U Oz Ounce U Ozt Troy Ou...

Страница 23: ...eries are converted with the following values 1g 0 001kg 1000mg 5ct 0 266667 mom 0 00220462 Lb 0 0352740 Oz 0 0321507 Ozt 0 0267173 TL HK 0 0264555 TL Singapore 0 0266667 TL Taiwan 0 0264600 TL Malays...

Страница 24: ...ormat Operate the keys according to the following descriptions and perform each setting is the current setting iF USEr io b b 300 Sets the baud rate to 300 bps b 600 Sets the baud rate to 600 bps b 12...

Страница 25: ...key Press the CAL MENU key A B io S S S1 Sets stop bit to 1 bit S S2 Sets stop bit to 2 bits io F F UF1 Sets data format to 1 F UF2 Sets data format to 2 F UF3 Sets data format to 3 F UF4 Sets data fo...

Страница 26: ...change in room temperature This feature is called Automatic Span Calibration PSC and is only available on the CAW series balances The stability of sensitivity is maintained within 2ppm regardless of...

Страница 27: ...everal seconds and the display returns to mass display 11 The calibration result is output to an external unit if the GLP GMP corresponding output is ON 7 2 Span Calibration Using an External Weight T...

Страница 28: ...n check using the built in weight Procedure 1 Warm up the balance F See Section 3 WARM UP 2 Verify that the balance is level 3 Verify that the balance pan is empty and press the O T key to zero the di...

Страница 29: ...ey several times When Func SEL is displayed press the O T key 5 Press the O T key when CAL is displayed 6 Press the CAL MENU key When E tESt is displayed press the O T key Span check starts at this po...

Страница 30: ...D 1 From the mass display press the CAL MENU several times When FunC SEL is displayed press the O T key 2 Press the CAL MENU key several times When bAnd is displayed press the O T key The indicates th...

Страница 31: ...erence values 10 1 Percentage Procedure This balance is capable of displaying mass values in the unit by setting a reference sample as 100 1 Register the unit F See Section 10 REGISTRATION RELEASE AND...

Страница 32: ...larger the reference number the higher the accuracy of measurement The minimum unit mass is 0 0100 g Procedure 1 Register the number of pieces PCS unit F See Section 10 REGISTRATION RELEASE AND SELECT...

Страница 33: ...ENT UNITS 3 Set the specific gravity of the liquid F See Section 23 SOLVENT SPECIFIC GRAVITY FOR SOLID SPECIFIC GRAVITY MEASUREMENT 4 Press the UNIT key from the mass display to select d While measuri...

Страница 34: ...SELECTION OF MEASUREMENT UNITS 3 Set the sinker volume for the measurement of liquid specific gravity 4 F See Section 24 SINKER VOLUME FOR LIQUID SPECIFIC GRAVITY MEASUREMENT 5 Press the UNIT key fro...

Страница 35: ...Auto Print function is active and oF indicates that the function is released 3 To change the settings press the O T key while AtPrt is displayed 4 Each time the CAL MENU key is pressed the display sw...

Страница 36: ...s the POWER BRK to send the total weight to the printer and return to normal weighing mode With printer attached Sample weight is sent to the printer upon stabilization followed by automatically retur...

Страница 37: ...n calibration and appears in the Operation Menu Setting the Standard Span Calibration Procedure 1 From the mass display press the CAL MENU key several times When SEttinG is displayed press the O T key...

Страница 38: ...5 When CAL SEt is displayed press and hold the POWER BRK key to return to mass display 16 EXTERNAL WEIGHT VALUE FOR BUILT IN WEIGHT CALIBRATION CAW CAX series only Procedure 1 From the mass display pr...

Страница 39: ...placed on the pan inside the balance 10 When PcAL 0 is displayed the balance verifies the zero point again 11 Span calibration of the built in weight is complete when the display returns to the mass d...

Страница 40: ...to GLP GMP on indicates that the function is active and oF indicates that the function is released 3 Press the O T key to change the setting 4 Each time CAL MENU is pressed GLP oF or GLP on is display...

Страница 41: ...mately two minutes To skip the span calibration press the POWER BRK key while the weight symbol is blinking Procedure 1 Press the CAL MENU key several times from the mass display When SEttinG is displ...

Страница 42: ...nge the setting 4 Each time CAL MENU is pressed tCAL oF or tCAL on is displayed The current setting is displayed with the stability symbol When the desired item is displayed press the O T key to chang...

Страница 43: ...IC GRAVITY MEASUREMENT Procedure 1 From the mass display press the CAL MENU key several times When SEttinG is displayed press the O T key 2 Press the CAL MENU key several times When LSG SEt is display...

Страница 44: ...5 DATE CAW CAX series only Procedure 1 From the mass display press the CAL MENU key several times When SEttinG is displayed press the O T key 2 Press the CAL MENUkey several times d MM DD is displayed...

Страница 45: ...old the POWER BRK key to return to mass display Entering the Time 1 From the mass display press the CAL MENU several times When SEttinG is diplayed press the O T key 2 Press the CAL MENU key several t...

Страница 46: ...ge the setting press the O T key while Prtdt is displayed 4 Each time the CAL MENU key is pressed the display switches between Prtdt oF and Prtdt on 5 Press the O T key to change the setting or press...

Страница 47: ...ght 3 Balance operation is normal if the values of both x and y are less than 1 5 times the standard deviation specified in Section 31 SPECIFICATIONS Corner Load Error Off center error or Eccentric er...

Страница 48: ...e installation site Change the average time and stability detection band Volatile sample Put a lid on the sample before weighing it Sample is charged Put the sample in a metallic container and then we...

Страница 49: ...conds and reconnect If this display is left on the balance for more than 24 hours it may not be possible to perform correct measurement During measurem ent The data cannot be transmitted to or receive...

Страница 50: ...ng PCAL Use the correct calibration mass CAL E4 Sensitivity deviates largely during span calibration Use the correct calibration mass CHE x The balance stops at this display S Err 0x The internal part...

Страница 51: ...2ppm When PSC is ON 2ppm C When PSC is OFF 2ppm C Operating temperature range 5 to 40 C Power supply Input 100 250VAC 47 63Hz 0 3A Output 12VDC 1A Model CAX120 CAY220 CAY120 Weighing capacity 120g 220...

Страница 52: ...Maintenance Parts Part name Part No Remarks Pan 321 60453 Pan supporter 321 60459 Including cushion Anti drift ring 321 41205 AC adaptor 074 83004 01 Level screw 321 53530 30 Glass door ASSY right 32...

Страница 53: ...activate Windows 6 Select Start Setting Control Panel Accessibility Options 7 Confirm that there are no check marks next to any items on any of the tabs including General 8 Place a check mark on Suppo...

Страница 54: ...es may be limited CAS does not guarantee that this function can be used on all the PCs without any problems currently or in the future CAS is not liable for any direct or indirect problems caused by t...

Страница 55: ...function may operate incorrectly if interval of data transmission is too short Do not touch the keyboard or the mouse while the balance is transmitting data Stop the data transmission and confirm that...

Страница 56: ...Polarity positive space negative minus Stability information available to output with stability information Stable S Unstable U When oL or oL is displayed U oL DL Polarity positive space negative min...

Страница 57: ...to indicate the stability state when the measurement was taken S Indicates the stability symbol was illuminated U Indicates the stability symbol was not illuminated D08 One time output at the stable...

Страница 58: ...Section 10 REGISTRATION RELEASE AND SELECTION OF MEASUREMENT UNIT C02 High Stability mode setting C13 Sample Pouring mode setting C14 Standard setting C05 Stability detection baud 0 1 mg C06 Stability...

Страница 59: ...DATA I O EP 60A The cable is a standard accessory of the printer KEYBOARD NEC PC98 series RS 232C cable RS 232C 25p 25p 1 5m Null modem IBM PC AT Compatibles RS 232C cable 25p 9p 1 5m Null modem DC I...

Отзывы: