50LC*D07---D12
Nominal 6 to 10 Tons
With Puron
(R---410A) Refrigerant
Service and Maintenance Instructions
TABLE OF CONTENTS
SAFETY CONSIDERATIONS
1
. . . . . . . . . . . . . . . . . . . .
UNIT ARRANGEMENT AND ACCESS
2
. . . . . . . . . . .
SUPPLY FAN (BLOWER) SECTION
3
. . . . . . . . . . . . . .
COOLING
5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PURON
R
(R--410A) REFRIGERANT
7
. . . . . . . . . . . . . .
COOLING CHARGING CHARTS
9
. . . . . . . . . . . . . . . . .
CONVENIENCE OUTLETS
15
. . . . . . . . . . . . . . . . . . . .
SMOKE DETECTORS
16
. . . . . . . . . . . . . . . . . . . . . . . . .
PROTECTIVE DEVICES
23
. . . . . . . . . . . . . . . . . . . . . . .
ELECTRIC HEATERS
24
. . . . . . . . . . . . . . . . . . . . . . . . .
WIRING DIAGRAMS
27
. . . . . . . . . . . . . . . . . . . . . . . . .
HACR
34
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ISC BOARD
37
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ECONOMI$ER X (FACTORY--INSTALLED)
39
. . . . . .
ECONOMIZER CONTROL CONFIGURATIONS
46
. . .
VARIABLE FREQUENCY DRIVE (VFD)
60
. . . . . . . . .
PRE--START-UP
82
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
START-UP, GENERAL
82
. . . . . . . . . . . . . . . . . . . . . . . . .
FASTENER TORQUE VALUES
83
. . . . . . . . . . . . . . . . .
MODEL NUMBER SIGNIFICANCE
84
. . . . . . . . . . . . .
SEQUENCE OF OPERATION
85
. . . . . . . . . . . . . . . . . . .
PHYSICAL DATA
87
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GENERAL FAN PERFORMANCE
93
. . . . . . . . . . . . . . .
START-UP CHECKLIST
99
. . . . . . . . . . . . . . . . . . . . . . .
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment
can be hazardous due to system pressure and electrical
components. Only trained and qualified service personnel
should install, repair, or service air-conditioning
equipment. Untrained personnel can perform the basic
maintenance functions of replacing filters. Trained service
personnel should perform all other operations.
When working on air-conditioning equipment, observe
precautions in the literature, tags and labels attached to
the unit, and other safety precautions that may apply.
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for unbrazing operations.
Have fire extinguishers available for all brazing
operations.
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for brazing operations. Have
fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions attached to
the unit. Consult local building codes and National
Electrical Code (NEC) for special requirements.
Recognize safety information. This is the safety--alert
symbol
. When you see this symbol on the unit and in
instructions or manuals, be alert to the potential for
personal injury.
Understand the signal words DANGER, WARNING, and
CAUTION. These words are used with the safety--alert
symbol. DANGER identifies the most serious hazards
which
will
result in severe personal injury or death.
WARNING signifies a hazard which
could
result in
personal injury or death. CAUTION is used to identify
unsafe practices which
may
result in minor personal
injury or product and property damage. NOTE is used to
highlight suggestions which
will
result in enhanced
installation, reliability, or operation.
Содержание 50LC 07
Страница 9: ...9 COOLING CHARGING CHARTS C150169 Fig 9 Cooling Charging Charts 07 ...
Страница 10: ...10 COOLING CHARGING CHARTS C150172 Fig 10 Cooling Charging Charts 08 ...
Страница 11: ...11 COOLING CHARGING CHARTS C150170 Fig 11 Cooling Charging Charts 09 ...
Страница 12: ...12 COOLING CHARGING CHARTS C150171 Fig 12 Cooling Charging Charts 12 ...
Страница 27: ...27 C150181 Fig 34 50LC 07 Control Wiring Diagram ...
Страница 28: ...28 C150225 Fig 35 50LC 07 RTU Open Control Wiring Diagram ...
Страница 29: ...29 C14095 Fig 36 50LC 07 Power Wiring Diagram 208 230V 460V and 575V Units ...
Страница 30: ...30 C14013 Fig 37 50LC 08 12 Control Wiring Diagram ...
Страница 31: ...31 C14104 Fig 38 50LC 08 12 RTU Open Control Wiring Diagram ...
Страница 32: ...32 C14105 Fig 39 50LC 08 12 Power Wiring Diagram 208 230V Units ...
Страница 33: ...33 C150216 Fig 40 50LC 08 12 Power Wiring Diagram 460V 575V Units ...
Страница 57: ...57 C13683 Fig 62 Typical EconoMi er X Wiring Diagram ...