CP3 version 3003
52
Select the number of sensors which must be assigned for the lines and also select a time delay. Default is
10 sec.
Press ‘Confirm’ to accept and to start the assign sequence.
LED feedback from sensors
: Assigned sensors without Lane, Line, Position address ( see above screenshot)
will start flashing yellow slowly (1Hz)
Go to line 1 and press the button on the first sensor. This sensor will get position 1 in line 1.
LED feedback from sensors
: Sensor 1 will change from blinking yellow to blinking green (3Hz) for 3 sec. and
then change to blinking green slowly (1Hz). The other sensors continue to blink yellow (1Hz). Continue
pressing all the sensors in consecutive order in line 1.
Press the button on the last sensor in line 1
LED feedback from sensors
: All the sensors will turn green for 10 sec (preselected time delay, defined in
assign mode. See above). This time delay is adjustable (default 10 sec) and indicates that line 1 assignment
has ended and that you can start line 2. After the time delay has expired, the LEDs on the sensors from line
2 and forward will start flashing yellow (sensors not yet configured), and you can continue assigning the
sensors to the correct positions until all sensors has been assigned.
It is very important to assign the sensors in consecutive order, so the sensors are referring to the correct
physical position on the line. If this rule is not observed, the sensors do not refer to the correct position and
the assign sequence must be repeated until it is correct.
When the assignment has ended, remember to save and upload the configuration to the carpark controller.
Assigning Display Interface Modules (DIM)
The DIM is not assigned in the same way as the sensor, but in configuration mode, the DIM must be
assigned a unique name and a display type (2 digits, 3 digits etc.).
To find the correct DIM in the list, use the SIN number and compare this with the physical SIN number on
the module.