CP3 version 3003
32
3 * 1.5 mm
2
(14-16AWG), non-shielded, multi-core wire with ferrule
3 * 1.5 mm
2
(14-16AWG) single-core wire
Practical Cabling Techniques
The following issues must be taken into consideration when installing the Dupline® bus cable.
• Do not mount the Dupline® bus cable close to high voltage installations such as:
• Motors
• High voltage cable
• Inverters
• Breakers
• Make sure that water cannot penetrate the Dupline
®
bus cable or junction boxes. Water can cause poor
connections and random activations of the sensors
• If the cable is installed close to high voltage cables or equipment, use a shielded cable
Selecting the Sensor Type
Depending on the installation, we must decide which sensor to use. In most installations we will use the 45-
degree angled sensor. For best performance it is recommended to mount the 45-degree sensor in height of
2.5 m at the entrance of the parking space. If there are obstacles lower than the sensor, a calibration of the
sensor can be difficult. Before calibration, the user is asked to enter the distance (from sensor to floor. 90