Installation of the PGS
Short Installation
In this section, the installer is given a tool to answer most questions that arise during the installation of
cables. Now the planning has ended, and we move forward towards the installation process starting with:
SBPSUSL45 Carpark Lane Sensor (Used in Most Installations)
Sensors must be installed at a distance of minimum 2.0 m (6.56 feet) and maximum 2.5 m (8.2 feet) from
the floor.
Use for instance cable trays to mount the sensors and Base A and the base holder SPB2BASEA to save
labour costs.
If the base holder is mounted directly on the ceiling, use the base holder SBP2BASEB (for pipe installation).
Make sure that Base A (B) is mounted correctly, so when the sensor is mounted it is pointing towards to
carpark space. For best performance it is recommended to mount the sensor in height of 2.5 m at the
entrance of the parking space. Refer to section ‘Placing the sensor’.
For aesthetic reasons, mount the sensors in a straight line and at the same height.