Make sure that the base is mounted so that the connectors in the base are pointing towards the carpark
space. See the pictures below. See also under section ‘Position of sensors’.
The vertical carpark sensor must be mounted in the middle of the carpark space pointing directly down to
the floor. The sensor must be mounted in an aesthetic manner maximum 4 m from the floor.
In both choices it is important to obey the rules of m/-5-degree vertical deviation and +/-2-degree
horizontal deviation for the lane mounted sensor. See section below: Positioning of sensor.
Please install the sensor according to the datasheet.
In the planning stage, decisions must be made as to where and how to mount the sensors. The decisions
based on physical conditions will include:
• On the ceiling
• On a cable tray
• As a lowered sensor
Each technique can be used, but installation time, price and aesthetic considerations must be taken into
account.
In our experience, cable tray installation is a very quick installation. In addition, it is cheap (in Europe
because of the labour) and it has a nice (aesthetic) appearance. In Asia experience has shown that
customers prefer the lowered sensor installation.
Sensors mounted on a cable tray
Place the base connectors so they are
pointing towards the carpark space
Place lane-mounted sensor correct outside the carpark
space in an atheistic manner.