Model 601GAS burner — Instruction manual

MN601GAS  012516

– 12 –

Where appliance instructions differ from this manual, follow the appliance instructions.

Mount burner in appliance

•  Verify appliance burner front plate dimensions and bolt locations.

•  Slide gasket supplied with burner over end of air tube.
•  Insert burner into appliance opening and bolt in place.
•  Level the housing if necessary by loosening the set screws securing the 

housing to the air tube. Retighten the set screws.

Inspect components and wiring

•  Visually inspect all burner components and wiring.
•  Verify that wiring is intact and leads are securely connected.
•  Verify that all burner components are in good condition.
•  Check gas pressure switch settings. Set the low and high gas pressure 

switch settings to +/- 50% of manifold setting.

Figure 8

 

Gas orifice location

Install gas train on burner

1.  The standard burner gas train is shipped fully assembled, with the piping 

disconnected at the gas train union. See separate instructions if installing 

an optional knocked down gas train. The gas train is available as angled 

(standard) or straight (alternate) construction.

2.  Connect the gas train at the union (Figure 9).

  To avoid damage to gas train components, do not hold compo-

nents with a pipe wrench or overtighten. Use only a crescent 

wrench or other means. Failure to comply could result in severe 

personal injury, death or substantial property damage.

3.  Connect the flexible conduit, pre-attached to the primary control J-box, 

to the gas train J-box, and attach the wires to the terminal strip inside 

the gas train J-box.

a.  Match wire colors of the incoming wires to those pre-wired to the terminal 

strip inside the gas train J-box.

b.  See the label in the burner junction box or the wiring diagram on page 15.

  Gas valve vent opening — If local codes require, install piping 

from vent connection to outside, sized and installed per code. A 

vent limiting orifice is provided. Install in vent opening, if starts 

are hard, before piping vent to outside.

  The two-stage regulating diaphragm gas valve on Massachusetts 

Code burners uses an interanl bleed, and does not require an 
external bleed connection.

Figure 9

 

Gas train installation

Inspect/redrill gas orifice

  If the burner is installed, you must disconnect power to burner 

and close main manual gas valve before proceeding. Failure to 

do so could result in severe personal injury, death or substantial 

property damage.

  In the state of Massachusetts, when lever-type gas shutoffs 

are used, they must be T-handle type only.

1.  Turn off power to the burner/appliance before proceeding.
2.  Close main manual gas valve in gas supply line to burner.
3.  Disconnect the burner gas train union if the burner/gas train is installed. 

See Figures 8 and 9.

4.  Locate the correct orifice drill size in Table 1a, page 9 (or appliance 

manual). Then check actual orifice size using that size drill bit.

5.  If the gas orifice is smaller than required, unscrew the orifice nipple 

from the elbow. Then redrill the orifice to the correct size. Replace the 

gas train, using only pipe dope listed for use with liquefied petroleum 

gases.

6.  If the gas orifice is larger than required, remove the orifice nipple from 

the elbow. Obtain a replacement orifice nipple. If necessary, drill the 

correct orifice hole in the new orifice to the correct size.

7.  Replace gas train. Seal pipe joints with a small amount of pipe dope. 

Use only pipe dope approved for use with liquefied petroleum gases.

1.  Prepare site   •   prepare burner   •   mount burner 

(continued)

  The orifice end of the orifice nipple must face the gas train.

Содержание 601GAS

Страница 1: ...pply pressure 5 inches w c Manifold pressure 3 5 inches w c Electrical Power 120V 60 Hz 1 Phase Motor Marathon PSC 1 2 HP 3450 RPM 8 4 amps Total Current Approx less than 10 amps Ignition Carlin Model...

Страница 2: ...Model 601GAS burner Instruction manual MN601GAS 012516 2 Where appliance instructions differ from this manual follow the appliance instructions...

Страница 3: ...husetts require a nonre cycle primary control and gas train Make sure the burner is properly equipped for Massachusetts installations United States installations Burner appliance installations in the...

Страница 4: ...d burner flange door for access and removal of combustion head gas manifold assembly 10 Ignitor Carlin Model 41000 solid state electronic ignitor 14 000 volts continuous duty rated 11 Hinged cover pla...

Страница 5: ...01GAS 012516 5 Where appliance instructions differ from this manual follow the appliance instructions 601GAS burner at a glance ITEM 17 MassachusettsCodeburnersalsoinclude an 8 second time delay relay...

Страница 6: ...hat has one or more sides exposed to the outside Install a listed stainless steel liner to vent the flue products A defective vent system could result in severe personal injury death or substantial pr...

Страница 7: ...tion manual when available to size combustion air openings Use the following guidelines when appliance instructions are not available All air from inside building building must be well ventilated Size...

Страница 8: ...s chamber liners may contain carcinogenic particles chrystobalites after exposure to heat Airborne particles from fiberglass or ceramic fiber components have been listed as potentially carcinogenic by...

Страница 9: ...NA 31 32 9687 21 32 6562 5 5 1 350 000 NA NA NA NA NA NA 1 1 000 11 16 6875 6 1 400 000 NA NA NA NA NA NA 1 1 16 1 063 23 32 7187 6 5 1 450 000 NA NA NA NA NA NA 1 1 8 1 125 3 4 7500 8 75 1 500 000 N...

Страница 10: ...ir tube insertion length Btuh L W C L H VC Dry Wet Dry Wet Dry Wet Wet Dry Wet 700 000 18 22 16 18 7 5 8 5 19 16 22 Welded flange Burners with welded flange have fixed usable tube length UTL set for t...

Страница 11: ...proceeding b Close the manual gas valve on the gas supply line c Disconnect the burner gas train union d Remove the gas pipe at the burner air tube e Remove the four nuts securing the burner hinged do...

Страница 12: ...in J box b See the label in the burner junction box or the wiring diagram on page 15 Gas valve vent opening If local codes require install piping from vent connection to outside sized and installed pe...

Страница 13: ...y pressure 5 inches w c Do not expose the gas train to gas pressure in excess of 14 inches water column Higher pressure could damage the valve seat resulting in potentially hazardous condition When pr...

Страница 14: ...roximately Approximate amp draw Motor 1 2 HP During ignition Add 0 5 amps to steady current below Steady operation Carlin motor 5 2 AMPS Marathon motor 8 4 amps 2 The 120 vac power connections to the...

Страница 15: ...nstructions differ from this manual follow the appliance instructions Figure 11 Wiring diagrams 601GAS burner with 60200FR primary control typical Standard Commercial Gas Train 120V Ventless Commercia...

Страница 16: ...joints near burner and check for any leaks If any leaks appear repair before proceeding and retest Set burner air damper See Figure 12 Loosen air damper locking nut Then rotate the ajustment screw un...

Страница 17: ...eset control from Latch up Press for 30 second Display Control ESC Display previous Operating State from Operating screen Exit Log or Setup screen to Operating screen with 3 second press Scroll throug...

Страница 18: ...n TFI or Post purge Motor ignitor or valve relay weld detected If the control is miswired causing voltage to be detected on the outputs terminals motor ignitor or valve when not ex pected Recycle limi...

Страница 19: ...urrent causes the cycle to be faulted Recycle Yes if a recycle occurred in CFH cycle A recycle causes the cycle to be faulted No Run time Time motor output is on during this cycle Burn time Time valve...

Страница 20: ...ac Check all electrical connections Control is in lockout Press the reset button for 1 second Other no start problems Line voltage 90 VAC Check line voltage 132VAC Motor relay welded If valve ignitor...

Страница 21: ...per appliance instruction manual Burner components settings verified against Table 1a page 9 Burner appliance installed per all applicable codes Installation site has adequate ventilation openings and...

Страница 22: ...the manifold gas pressure with the manometer Set the high gas pressure switch to a pressure less than actual manifold pressure The high gas pressure switch should shut the burner down Replace the swi...

Страница 23: ...erform the complete checkout procedures of pages 16 through 22 including system inspection and checks 6 Maintenance and service procedures Maintenance service procedures Cleaning blower wheel 1 The bl...

Страница 24: ...e door is closed securely and that door switch is closed Gas pressure Check low gas pressure switch If it is open gas supply may be too low or no gas flow check supply line and manual valves Gas train...

Страница 25: ...ifice size Check gas orifice size See Table 1a page 9 Manifold pressure Check gas manifold pressure should be between 3 2 and 3 8 inches w c unless specified Low gas supply pressure Check line pressur...

Страница 26: ...9147 99427 9a Static disc Built into 1x and 2x heads non removable not used in 3x heads NA 9b Diffuser plate 1x heads only 99162 Combustion head assemblies 11 combustion head assembly includes items s...

Страница 27: ...follow the appliance instructions 8 Replacement parts Burner continued Set screws Combustion head assembly Burnerisshownwithweldedflange suppliedonlyonburners ordered for specific appliance applicatio...

Страница 28: ...surized firing Failure to comply could result in severe personal injury death or substantial property damage When using a welded flange burner verify the insertion depth on the appliance and burner se...

Страница 29: ...Model 601GAS burner Instruction manual MN601GAS 012516 29 Where appliance instructions differ from this manual follow the appliance instructions...

Страница 30: ...model Serial number Measured firing rate Btuh Gas orifice drill size Manifold gas pressure IWC Inlet gas pressure IWC r p r o l a r u t a n l e u F 2 O 2 O C opane Were controls tested Comments about...

Отзывы: