1.  WARNINGS 

1.1  General warnings

This document is the set of original instructions written in Italian; all other 
languages have been professionally translated. For the intended meaning 
reference must always be made to the original Italian version.
The HEOS BOX units are water-cooled condensing units for indoor 
use, intended for medium (MT) and low temperature (LT) commercial 
refrigeration applications. HEOS BOX is a partly-completed machine and 
as such must be appropriately connected to an evaporating system in 
order to function correctly. HEOS BOX and the evaporating unit together 
comprise the complete equipment. Carefully read this booklet and all 
documentation supplied with the unit. This documentation must be kept 
by the customer (manufacturer, designer, installer or owner of the final 
equipment) for any future maintenance or service. The warranty will be 
void if the instructions described under “Warnings” are not complied with.

The operation of HEOS BOX is specified in the technical 
documentation supplied with the product or can be 
downloaded, even prior to purchase, from the website 
www.carel.com. 

Every product supplied by CAREL Industries, in relation to its advanced 
level of technology, requires setup/configuration/programming to be 
able to operate in the best possible way for the specific application. Failure 
to complete such operations, which are required/indicated in the user 
manual, may cause the final product to malfunction; CAREL Industries 
accepts no liability in such cases. The customer (manufacturer, developer, 
installer or owner of the final equipment) accepts all liability and risk 
relating to the configuration of the product in order to reach the expected 
results in relation to the specific final installation and/or equipment. CAREL 
Industries may, based on specific agreements, act as a consultant for the 
installation/commissioning/use of the unit, however in no case does it 
accept liability for the correct operation of the unit and the overall system 
if the warnings or suggestions provided in this manual or in other product 
technical documents are not heeded. In particular, as well as observing 
the above warnings and suggestions, the following warnings must be 
observed for correct use of the product:

 ELECTRIC SHOCK HAZARD

The unit contains live electrical components. Disconnect the mains 
power supply before accessing inside parts or during maintenance and 
installation. It is forbidden to remove the access panels to the internal 
parts of the unit without first having placed disconnect switch QS1 and 
the switch or disconnect device on the HEOS BOX power supply line in the 
OFF position (see the wiring diagram). The mains power disconnect device 
must have a contact opening distance that allows complete disconnection 
in overvoltage category III conditions; it must also be incorporated into the 
HEOS BOX power supply line in accordance with national regulations.

 WATER LEAK HAZARD

The unit comprises components containing water or water with antifreeze 
additive (generally glycol). Malfunctions in the unit’s connections or to its 
operation may cause fluid leakages. Avoid direct contact of the fluid with 
the eyes/skin and, in the event of accidental contact or inhalation, seek 
medical advice.

 PRESSURE EQUIPMENT HAZARD

The unit is supplied sealed with an inert gas (nitrogen) pre-charge of 
around 1 bar (14.5 psi) above atmospheric pressure. Take all necessary 
precautions to avoid material from being expelled outside of the unit 
when venting the gas. Before charging the unit with R744 refrigerant, make 
sure that all the activities described in the “Introduction”, “Handling” and 
“Installation” chapters have been completed, including connection of the 
high pressure safety valve discharge to suitable piping, so as to discharge 
excess pressure safely away from the equipment. Carefully verify the PS 
and TS after having incorporated the HEOS BOX into the evaporating 
system, considering all the components of the refrigerant circuit (for the 
refrigerant circuit contained inside HEOS BOX, refer to the values shown 
on the unit’s label and reported in this manual).  Always wear protective 
glasses when performing any work on the unit.

 BURN HAZARD

The unit contains components that may reach high temperatures. Take all 
necessary protective measures before performing any operations on the 
unit.

  WARNINGS

•  HEOS BOX product is a component that can be integrated into various 

different applications. HEOS BOX installation requires the installer to 
ensure suitable protection against direct contact with hazardous high 
voltage parts. Under no circumstances should any live parts be accessed.

•  The installation of the product must include a compliant earth 

connection, using the yellow-green terminal provided inside the 
electrical panel.

•  Environmental and power supply conditions must conform to the 

values specified on the product rating labels.

•  Handling, installation, use and maintenance must be performed by 

qualified personnel who have the qualifications and authorisations 
required by local regulations, using appropriate personal protective 
equipment (PPE), who are aware of the necessary precautions and who 
are able to correctly and safely complete all required operations.

•  All operations on the product must be carried out according to the 

instructions provided in this manual and on the labels applied to the 
product. Any uses or modifications that are not authorised by the 
manufacturer are considered improper. CAREL Industries S.p.A. declines 
all liability for any such unauthorised use.

•  Keep all ventilation openings on the equipment’s enclosure or on the 

structure for built-in installation clear of obstructions;

•  Do not damage the refrigerant circuit 
•  Do not attempt to open the unit in any way other than described in 

the manual.

•  Observe the standards in force in the place where the unit is installed.
•  Keep the unit out of the reach of children and animals. The unit must be 

operated/serviced/cleaned by qualified adult personnel. The operations 
described above are therefore prohibited to minors or people with 
reduced psychophysical abilities.

•  Do not install and use the product near objects that may be damaged 

when in contact with water (or condensate). CAREL Industries S.p.A. 
declines all liability for direct or indirect damage following water leaks 
from the unit.

•  Do not use corrosive chemicals, solvents or aggressive detergents 

to clean the inside and outside parts of the unit, unless specifically 
indicated in the user manual.

•  Do not drop, hit or shake the unit, as the inside parts and the linings may 

be irreparably damaged.

•  If the unit is delivered arranged in a way other than that required for 

installation (upside down or on one side), wait at least 24 hours before 
starting it the first time.

Содержание HB200C0300CE0

Страница 1: ...C o n t r o l S o l u t i o n s E n e r g y S a v i n g s NO POWER SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT HEOS BOX R744 User manual Assembly instructions including user and maintenance inf...

Страница 2: ......

Страница 3: ...uit 12 2 11 Electrical panel 13 2 12 Requirements for positioning the unit and multi evaporator layout 14 3 HANDLING 19 3 1 Opening the packaging 19 3 2 Positioning the unit 19 4 INSTALLATION 21 4 1 M...

Страница 4: ......

Страница 5: ...EQUIPMENT HAZARD The unit is supplied sealed with an inert gas nitrogen pre charge of around 1 bar 14 5 psi above atmospheric pressure Take all necessary precautions to avoid material from being expe...

Страница 6: ...equivalent new equipment on a one to one basis or one to zero for equipment less than 25 cm on their longest side 3 the equipment may contain hazardous substances the improper use or incorrect dispos...

Страница 7: ...d with a Carel unipolar electronic expansion valve which is not supplied with the unit Appropriate sizing of the electronic valve where possible using Carel s selection tools allows Heosbox to be used...

Страница 8: ...configuration HBOPZGATY2000 Kit for supervisor WiFi connection HBOPZRAHY2000 Anti sweat heater management kit Tab 2 d 2 5 Connection diagrams local and su pervisor connection The Heosbox unit can be c...

Страница 9: ...y and therefore an external switch is needed for connection to the supervisory system Ethernet network Modbus Ethernet switch Fig 2 e On request a version of the controller with two Ethernet ports is...

Страница 10: ...edium temperature operation Evaporating temperature 10 C superheat 10 K subcooling 0 K condensing temperature 20 C compressor rotation speed 80 rps 4 Nominal conditions for low temperature operation E...

Страница 11: ...ulation of the current supplied by the electronic control does not include the optional anti sweat heater kit In fact the optional kit is not powered by the electronic controller but by the Heos Box m...

Страница 12: ...nser Water outlet connection Water inlet connection Suction pressure line Discharge Line Fig 2 h 2 26 30 29 1 14 15 8 12 13 25 22 6 17 16 23 24 4 9 10 11 27 19 18 7 20 28 21 5 3 Fig 2 i Ref Descriptio...

Страница 13: ...earth wire connection 43 Anti sweat heater kit 44 Electrical panel main switch 45 Electric panel ventilation air intake grille 46 Electrical panel power cable gland 47 Cable gland for digital output 6...

Страница 14: ...other acceptable configuration involves a common liquid line NB the last evaporator also needs to be well supplied with liquid and the suction lines in a multisplit arrangement Multiplex configuration...

Страница 15: ...ox Fig 2 p Heos Box lower than the evaporator P trap Reverse trap Suction line Heosbox Fig 2 q Possible oil top up Caution refer to section 4 6 2 12 3 Evaporator combination requirements When sizing t...

Страница 16: ...6 0 755 1 319 2 304 3 634 5 154 7 002 11 464 25 0 271 0 692 1 209 2 113 3 333 4 727 6 422 10 514 Tab 2 p MT application medium temperature Minimum cooling capacity in kW to ensure the oil is carried t...

Страница 17: ...ling capacity needed to carry the oil The tables below show the minimum cooling capacity as a function of Operating conditions Pipe diameter For the optimum diameter make sure that the required design...

Страница 18: ...420 5 395 7 652 10 396 17 020 20 0 409 1 043 1 821 3 181 5 019 7 117 9 670 15 831 25 0 375 0 956 1 670 2 917 4 602 6 526 8 867 14 516 Tab 2 w Minimum cooling capacity in kW to ensure the oil is carrie...

Страница 19: ...installed on the floor observing the clearances and making sure that there is natural ventilation to the unit Always avoid positioning installing the unit outdoors in a place where it is exposed to t...

Страница 20: ...ed for correct operation of the unit the following images show the distances from the surfaces to be allowed for during installation Side view Top view wall wall MIN 150 mm 5 91 in MIN 150 mm 5 91 in...

Страница 21: ...e using pipe couplings whose diameter and thickness varies according to the size of the unit see Refrigerant connections 4 1 Material supplied Heos Box is supplied complete with the following material...

Страница 22: ...ff placing disconnect switch QS1 and the switch or disconnect device on the HEOS BOX power supply line in the OFF position see the wiring diagram The mains power disconnect device must have a contact...

Страница 23: ...o the HEOS BOX power supply line in accordance with national regulations It is compulsory to follow the instructions on the wiring diagrams and comply with the minimum sizes of the multi core cables s...

Страница 24: ...gerant into the unit and are not technical specifications The expansion valves on the units must be correctly sized in order to complete the charging operation successfully CAREL Industries S p A may...

Страница 25: ...n 30 minutes 10 Disconnect the pump and close the discharge pressure port Fig 2 i 3 11 Carefully open the refrigerant inlet and outlet shut off valves Fig 2 i 18 and 21 4 8 2 Multi evaporator ME Cauti...

Страница 26: ...the Electrical Connections have been carried out as described in paragraph 4 4 4 Make sure that there is at least one display kit available see paragraph 2 3 If wanting to use the interface via smart...

Страница 27: ...outside of the unit Maintenance operations to be carried out every six months visually inspect the inside of the box every six months It is forbidden to remove the outer protection panels without firs...

Страница 28: ...l output 5 5 Free cable gland 1 17 Cable gland for digital output 6 6 Free cable gland 2 18 Heos electronic controller fuses 7 Free cable gland 3 19 Auxiliary terminals for optional anti sweat heater...

Страница 29: ...Now connect the wires downstream of the kit marked 08 and 09 to terminal J25 as shown on page QE EFS 7 of the panel s wiring diagram using a flat head screwdriver to help lever the spring When connect...

Страница 30: ...30 ENG Heos BOX R704 0300140EN rel 1 0 25 05 2022 Notes...

Страница 31: ......

Страница 32: ...BEL Caution Do not remove this copy of the unit label from the manual The customer is required to carefully keep all of the documentation supplied with the unit for any future maintenance or service U...

Отзывы: