IMPORTANT REMARkS
IMPORTANT REMARkS
IMPORTANT REMARkS
TO REDUCE THE RISk OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARkS CARE-
FULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO
ALL THE PARAGRAPHS MARkED WITH THE SYMBOL
. NOT READING THESE IMPORTANT
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORkING ORDER OF THE SYSTEM.
AUTOMATIC OPENING
kEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
WARNING
• These instructions are aimed at professionally qualified "
INSTALLERS
OF ELECTRICAL EQUIPMENT" and must respect the local standards
and regulations in force. All materials used must be approved and
must suit the environment in which the installation is situated.
• All maintenance operations must be carried out by professionally
qualified technicians. Before carrying out any cleaning or maintenance
operations make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it
has been made. "i.e.
for the automation of one or two hinged gates".
The self-locking
230Vac electromechanical operator 200/BL1920 is
suitable for hinged gates up to
2,0 m in length and 150 kg in weight
(per gate leaf).
• The unit may be fitted both to the
right and to the left of the pas-
sageway.
• This product and all its relative components has been designed and
manufactured by Cardin Elettronica who have verified that the product
conforms in every aspect to the safety standards in force.
Any non authorised modifications are to be considered improper and
therefore dangerous.
The manufacturer accepts no liability for situations arising from the
use of an electrical installation which does not conform to the local
standards and regulations in force and in particular when the earthing
circuit is not efficient.
IMPORTANT! The geared motor is not fitted with a torque limiter.
Only use an electronic programmer which has a torque limiter
with maximum force at the head of the gate equal to
150 N.
It is the responsibility of the installer to make sure that the following
public safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from
the main road to eliminate possible traffic disruptions.
2) The operator must be installed on the inside of the property and not
on the public side of the gate. The gates must not swing outwards
onto a public area.
3) The gate operator is designed for use on gates through which vehicles
are passing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls
must be situated in a position where the operator can see the gate
at all times.
5) At least two warning signs (similar to the example
on the right) should be placed, where they can be
easily seen by the public, in the area of the system
of automatic operation. One inside the property
and one on the public side of the installation.
These signs must be indelible and not hidden by
any objects (such as tree branches, decorative
fencing etc.).
6) Make sure that the end-user is aware that children and/or pets must
not be allowed to play within the area of a gate installation. If possible
include this in the warning signs.
7) Whenever a fully open gate leaf comes within at least
500 mm of
a fixed structure the space must be protected by an anticrush
buffer.
8) A correct earth connection is fundamental in order to guarantee the
electrical safety of the machine
9) If you have any questions about the safety of the gate operating
system, do not install the operator. Contact your dealer for assist-
ance.
TECHNICAL DESCRIPTION
-
230Vac motor.
- Carter in shock-proof plastic.
- Release mechanism components in shockproof plastic.
- Geared motor with steel gears enclosed in a die cast two-piece
aluminium shell.
- The geared motor is fitted with two micro switches; one for closing
"
FCC" and one for opening "FCA" (see wiring diagram).
- Motor support base in zinc-plated steel
- Articulated operator arm in die cast aluminium
- Lubrication using permanently fluid grease.
ACCESSORIES
980/xLSE11C - Electric lock 12 Vac.
The appliance is not suitable for continuous operation and must be
adjusted according to the technical data on page 20.
The minimum controls which may be installed are OPEN-STOP-
CLOSE, these controls must be installed in a location not accessible
to children.
Before starting with the installation of the system check that the structure
which is to be automated is in good working order and respects the
local standards and regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary
reinforce the structure) and that the hinges turn easily.
You are advised to grease all the moving parts using lubricants which
maintain unaltered friction characteristics over a period of time and are
suitable for temperatures of
-20 to +70°C.
• Check the safety measures between the fixed and moving parts:
- a minimum space of
30 mm must always be left along the entire
distance between the gate and the support column measured
throughout the entire opening angle of the gate.
- make sure that the space between the bottom of the gate and
the pavement never exceeds
30 mm throughout the entire opening
angle of the gate.
• The surface of the gate must not feature openings which allow a
person’s hand or foot to pass through.
• Check the exact positioning of the pivots and hinges, and their good
working order (the upper and lower hinges/pivots must be aligned
on the same axis).
• Work out the run of the cables according to the command and con-
trol devices fitted and make sure the system conforms to the local
standard and regulations in force (see installation example figure 1
pag. 2).
• Check that the appliance is suitable for the size, weight and duty
cycle of the gate to which it is to be applied (see duty cycle on page
20).
INSTALLATION INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS