Shth Sen Err....................... Indicates that the sheet tester measured pressure at the start of a cycle.
Start .................................. Indicates when a cycle was started.
Sth Disabled ...................... Indicates that the sheath (leak) tester was disabled.
Stop ................................... Indicates when a cycle was manually stopped.
Temp = .............................. Indicates the basin temperature at the beginning and end of the disinfect phase.
Water T High ...................... Incoming water temperature exceeding maximum allowed.
Water T Low ....................... Incoming water pump below the minimum around
Glossary of Terms
basin.................................. chamber into which the endoscope is placed for disinfection.
cleaning ............................. physical removal of organic debris from an endoscope.
control panel ...................... operator interface used to program and operate the reprocessor.
custom program ................ disinfection program other than the default program.
cycle .................................. sequence of phases in the disinfection process: detergent flush, basin fill,
..........................................
disinfection, rinse, alcohol purge, and air purge.
default program ................. disinfection cycle program supplied with the reprocessor.
disinfection procedure........ pre-programmed series of phases that collectively constitute a specified
..........................................
disinfection protocol function any operation other than a disinfection program,
..........................................
example: disinfectant dump function.
high-level disinfection ........ process defined by the CDC that destroys all vegetative bacteria, viruses, and
..........................................
fungi, but not necessarily all bacterial endospores.
idle state ............................ standby operating state during which no program cycles or other functions are in progress.
MRC................................... Minimum Recommended Concentration.
phase................................. specific portion of a disinfection cycle.
reservoir ............................ container that holds disinfectant, alcohol, or detergent.
restrictor adapter ............... used to simulate a scope during certain operations. This part is supplied with
..........................................
the reprocessor installation kit.
running state ..................... operating state during which a program is in progress, or some other function is
..........................................
occurring (i.e., any state other than idle or stop).
station ............................... part of the system used to disinfect a single endoscope. The station includes the
..........................................
basin, fluid reservoir, valves, hoses, pump, and compressor.
status indicator .................. blinking symbol on the control panel display indicating the current operating state.
status log ........................... stored record of recent disinfection cycles containing usage history, error status,
..........................................
and processed endoscope serial numbers.
stop state ........................... operating state during which a disinfection protocol is in progress, but the current
..........................................
cycle is suspended.
SSG ................................... Sign Shot Generator
Содержание MEDIVATORS DSD EDGE
Страница 1: ...1 Service Manual System Version 5 65...
Страница 23: ...23 Figure 5 Function Keys...
Страница 27: ...27 Figure 6 Set Date Screen...
Страница 29: ...29 Figure 7 Set Time Screens...
Страница 31: ...31 Figure 8 Software Version Screen Flash Code Version or Software version Micro controller Code Version...
Страница 33: ...33 Figure 9 Display Log Screen and sample entry...
Страница 42: ...42 Figure 14 Custom Program Setup Screens P1 Detergent Inject Set Minutes 00 00...
Страница 43: ...43 Figure 15 Custom Program Setup Screen...
Страница 51: ...51 Figure 22 Set Delayed Startup Screen...
Страница 54: ...54...
Страница 96: ...96 Notes...
Страница 101: ...101 Figure 4 Depress locking ring Figure 5 Insert tube Figure 6 Locking ring out...
Страница 107: ...107 Figure 14 Install the new water filter Figure 15 Reconnect the water filter Figure 16 Filter installed...
Страница 109: ...109 Figure 17 LCD Display Figure 18 Drain Purge Line Figure 19 Replace Pre filters 1 MICRON 0 45 MICRON...
Страница 111: ...111 Figure 20 Printer compartment Figure 21 Advance paper Figure 22 Feed paper through slot Figure 23 Install new roll...
Страница 115: ...115 Figure 28 Filter locations Figure 29 Disconnect the filter Figure 30 Verify inlet side...
Страница 119: ...119 Figure 33 Fuse locations...
Страница 121: ...121 Figure 34 Connect pressure gauge Figure 35 Bleed some air...
Страница 140: ...140 DSD EDGE W O RECIRC W ADDITIONAL ISOLATION VALVE W CHAMBER FLOW SWITCH HYDRAULIC SCHEMATIC REVISION 02...
Страница 141: ...141...
Страница 142: ...142...
Страница 143: ...143...
Страница 149: ...149...
Страница 150: ...150...
Страница 151: ...151...