Work
Remove the packing tape and the
DO NOT LIFT label from the
machine.
Lift the grip of the RDF unit to open.
Remove the two screws, and
remove the copyboard glass retainer
(right) and the copyboard glass.
Remove the lens metal fixing.
(Keep the metal fixing for possible
relocation of the machine.)
Butt the copyboard glass against the
front left, and install the copyboard
glass retainer right with two screws.
Open the left and right front doors,
and loosen the two screws to
remove the upper left cover; then,
remove the screw, and remove the
scanner metal fixing. (Keep the
metal fixing for possible relocation
of the machine.)
Install the upper left cover.
Checks/remarks
Remove the protection tape for the size index and the
protection material for the copyboard cover.
Screw
Lens metal fixing
Screws
Screw
Scanner
metal fixing
B. Installing the Lens/Scanner System
5. INSTALLATION
COPYRIGHT © 1996 CANON INC.
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)