COPYRIGHT © 1996 CANON INC.
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3. OPERATIONS AND TIMING
3-249
Screen 7-4
RFSKEW : 0 (1:EXECUTING)
RF_AE : 0 (1:EXECUTING)
RFSE_INT : 0 (1:EXECUTING)
✻
7
✻
APPLICATION
OK
Item
Description
Remarks
RFSKEW
RF_AE
RFSE_INT
Use it to execute automatic adjustment
of the RF skew detection reference
value. (See 1 and 3 of Note.)
Use it to execute automatic adjustment
of the RF AE sensor. (See 3 of Note.)
Use it to execute initial adjustment of the
RDF sensor. (See 3 and 2 of Note.)
Press the
key to start.
Press the
key to start.
Press the
key to start.
OK
OK
OK
Settings
Note:
1. Execute when replacing the RDF controller PCB, registration sensor 1, or skew sensor 1.
2. Execute when replacing the RDF controller PCB, original sensor 1, registration sensor 1, skew sen-
sor 1, manual registration sensor, image leading edge sensor, or original sensor 2.
3. The Copy Start key remains disabled when this screen is on to prevent malfunction.