COPYRIGHT © 1996 CANON INC.
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3. OPERATIONS AND TIMING
3-253
Cause
• Scanner (M2; fault)
•
.
Scanner home position sensor (Q5;
fault)
• DC controller PCB (fault)
•
.
Scanner home position sensor (Q5;
fault)
• Scanner motor (M2; fault)
• DC controller PCB (fault)
• Scanner motor (M2; fault)
• Scanner original leading edge sensor
(Q4; fault)
• DC controller PCB (fault)
• Scanner motor (M2; fault)
•
.
Scanner C.F.F. position sensor (Q6;
fault)
• DC controller PCB (fault)
• Lens X home position sensor (Q2;
fault)
•
.
Lens X motor (M9; fault)
• DC controller PCB (fault)
•
.
Lens Y home position sensor (Q3;
fault)
•
.
Lens Y motor (M10; fault)
• DC controller PCB (fault)
•
.
Scanner original leading edge sensor
(Q38: fault)
• DC controller PCB (fault)
•
.
Scanner cooling fan (FM1, FM10,
FM11; fault)
• DC controller PCB (fault)
Description
•
.
The scanner home position signal
(SCHP) is not generated within 10 sec
after the power switch or the Copy Start
key is pressed.
•
.
While the scanner motor drive signal is
being generated, clock pulses are not
generated within 2 sec.
•
.
The scanner leading edge signal
(SCDP1) is not generated within 0.8 sec
after the scanner has started to move
forward (within 3 sec for the C.F.F.).
•
.
The scanner leading edge signal
(SCDP1) is not generated within 1 sec
after the scanner has started to move in
reverse.
•
.
The scanner C.F.F. position signal
(SCFFP) is not generated within 10 sec
after the C.F.F. has been set.
• The lens X home position signal (LXHP)
is not generated within 9 sec after the
power switch or the Copy Start key is
turned ON.
• The lens X home position signal (LXHP)
is generated for 2 sec or more.
• The lens Y home position signal (LYHP)
is not generated within 9 sec after the
power switch or the Copy Start key is
turned ON.
• The lens Y home position signal (LYHP)
is generated for 2 sec or more.
•
.
In stream reading mode, the scanner ori-
ginal leading edge sensor 2 signal
(SCDP2) is not generated for 5 pages
continuously .
•
.
While the scanner cooling fan (FM1,
FM10, FM11) is rotating, an error signal
is generated for 2 sec or more.
*2
*2
E202
E203
E204
E209
E210
E212
E213
E214
Code
Содержание NP6085
Страница 8: ......
Страница 44: ......
Страница 46: ......
Страница 58: ......
Страница 100: ......
Страница 102: ......
Страница 425: ......
Страница 481: ......
Страница 483: ......
Страница 493: ......
Страница 498: ...COPYRIGHT 1996 CANON INC CANON NP6085 REV 0 JULY 1996 PRINTED IN JAPAN IMPRIME AU JAPON A 5 ...
Страница 502: ...PRINTED IN JAPAN IMPRIME AU JAPON 0697AB0 6 3 This publication is printed on 70 reprocessed paper ...