V. REMOTE DIAGNOSTIC
DEVICE II
Observe the following when installing the
device to the copier:
1. Follow the applicable laws of the respective
country.
2. Check to make sure that the copier has been
properly installed before starting the work.
3. Keep the copier’s power plug disconnected
during the work.
4. Identify the screws by type (length, diameter)
and location.
5. Keep the settings data for the device ready for
the computer installed at the service station.
1) Remove the two screws
w
of the top cover of
the device, and remove the cover
q
.
Figure 5-14
2) Connect the connector
t
of the power supply
unit to the connector
y
of the device.
Figure 5-15
3) Remove the four screws
i
, and remove the
four screws
i
from the face plate
u
of the
copier’s rear cover.
Figure 5-16