Step
5
6
7
8
Work
Release the feeding guide releasing
lever; then, pull out the drum
separation claw releasing plate in
upper left direction to remove.
Keep the drum separation claw
releasing plate for later use.
Remove the three
screws, and
remove the process cover.
Remove the four screws, and
remove the developing duct and
transfer charging dust-proofing fan.
Turn the developing assembly
locking lever counterclockwise to
release.
Remove the screw with a washer
tightened with the grounding wire;
then, remove the developing assembly
metal fixing.
Checks/remarks
Drum separation claw releasing plate
Feeding guide
releasing lever
Process cover
Duplexing unit
Screw
Screw
Screws
Developing duct
Developing
assembly
locking lever
Developing
assembly
metal fixing
Screw
Grounding
wire