15.Adjusting the Nip (tightening the pressure
adjusting hex nut)
Perform the following whenever you have
replaced the upper roller or the lower roller or if
fixing faults occur.
If the roller is cold, wait 15 min after the end of
the wait period and make 20 copies before taking
measurements.
1) Open the RDF, and select ‘NIP’ in service
mode (
).
2) Press the OK key on the LCD control panel
screen. (Paper will be discharged automatically.)
3) Measure the width of the area (Figure 4-836;
where toner is shiny). (The solid will be In
stripes.)
The measurement paper should be the sec-
ond drawing paper.
a and c are pits 10 to 15 mm on both edges
of the copy paper.
Figure 4-836
Table 4-801
4) If the dimensions are not as indicated, turn the
pressure adjusting nut at the rear and the front
to adjust.
16.Positioning the Guide Plate
Place the fixing assembly on a level surface,
and make adjustments so that the distance from
the surface is 52.7 ±0.2 mm as shown.
Figure 4-837
✽
3
✽
4. MECHANICAL SYSTEM
COPYRIGHT © 1996 CANON INC.
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-94
Note:
Feeding
direction
Center of
copy paper
A3 size
11x17" size
c
a
b
Dimension
b
| a – c |
Measured when both upper and
lower rollers are sufficiently heated
100V
150/
: 9.0
±
0.5 mm
208/220/240V : 10.5
±
0.5 mm
0.5 mm or less
Paper
guide mount
52.7
±
0.2mm
Содержание NP6085
Страница 8: ......
Страница 44: ......
Страница 46: ......
Страница 58: ......
Страница 100: ......
Страница 102: ......
Страница 425: ......
Страница 481: ......
Страница 483: ......
Страница 493: ......
Страница 498: ...COPYRIGHT 1996 CANON INC CANON NP6085 REV 0 JULY 1996 PRINTED IN JAPAN IMPRIME AU JAPON A 5 ...
Страница 502: ...PRINTED IN JAPAN IMPRIME AU JAPON 0697AB0 6 3 This publication is printed on 70 reprocessed paper ...