Type
Automatic logs
Manual logs
Continuous logs
Main Controller
Yes (more detailed than continu-
ous logs)
Yes (more detailed than continu-
ous logs)
Yes
DCON
Yes
Yes
No
RCON
Yes
Yes
No
Cases Where Debug Logs Need to Be Collected
• When the result of identification of the cause shows that the trouble was caused by the iR-ADV machine (firmware, hardware-
related controller)
• When the failure occurs only at the customer's site and cannot be reproduced by the department in charge of quality
management or Canon Inc.
■ Sublogs
Sublog is the general term for the unified logs for analyzing problem in which operation histories of software modules are compiled
as debug logs.
When a problem relating to the host machine occurs in the field and it is difficult to identify the cause of it at the user site, collecting
Sublogs and sending them to Design Dept./R&D can improve the efficiency of analyzing the problem and reduce the time it takes
to deal with the problem.
CAUTION:
• Since Sublogs are basically stored in volatile memory, almost all information will be lost by turning OFF and then ON
the power. Therefore, be sure to collect logs without turning OFF and then ON the power.
• I order to prevent failure of collecting necessary information because the log is overwritten with the succeeding process,
be sure to collect the Sublog while the symptom has occurred or immediately after the occurrence.
• Once the Sublog files are collected, they are deleted from the machine. In the case of collecting Sublogs consecutively,
the number of continuous log files may be fewer than usual.
■ Key Operation Logs
The key operation log function is used to collect user's key operation logs in order to distinguish between a host machine failure
and a user's operation mistake when, for example, a fax transmission error occurred.
If it cannot be denied the possibility that the user operation caused the error, collect the key operation logs.
Key operation logs are not recorded by default, therefore, the function needs to be enabled.
In order to save key operation logs, configure the setting of the following Settings/Registration menu to ON (enabled).
[Management Settings] > [Device Management] > [Store Key Operation Log]
Only when the foregoing setting is enabled, it is judged that user's permission has been obtained, and user operation logs start
to be recorded.
User operation logs are saved together with Sublogs and collected as logs contained in Sublog files.
Among the saved user operation logs, the confidential information shown below is masked.
• Password entered from the software keyboard
• PIN, PIN code, etc. entered from the Numeric Keypad
• Information that is hidden by turned letters on the UI screen
CAUTION:
Be sure to obtain user's permission in advance to record key operation logs for analyzing problems.
NOTE:
• When logs are output, passwords, PIN, and turned letters are masked, and these confidential information never leak out.
• Collect this log when it is determined that analysis of the debug log is required.
■ Network Packet Logs
With this function, network packet data sent from or received by the host machine is collected (captured) in the HDD without the
need for special equipment.
When it is expected that the trouble was caused by network, collect network packet logs.
Note that this function is not a standard function because packet data on the network contains customer information.
To use this function, it needs to be activated in the following menu and then enabled in service mode.
6. Troubleshooting
305
Содержание imageRUNNER ADVANCE C3500 III Series
Страница 1: ...Revision 2 1 imageRUNNER ADVANCE C3500 III Series Servie Manual ...
Страница 23: ...Safety Precautions Laser 2 Power Supply Lithium Battery 3 Toner Safety 4 Notes on works 4 ...
Страница 28: ...Product Overview 1 Product Lineup 7 Specifications 11 Parts Name 34 ...
Страница 153: ...Periodical Service 3 Consumable Parts List 132 Cleaning Parts 136 ...
Страница 158: ...Cleaning Parts 15 9 14 13 8 4 16 17 5 3 6 7 1 2 12 10 11 15 16 3 Periodical Service 136 ...
Страница 210: ... Procedure 1 Remove the 4 cables 4 Connectors 1 3 Wire Saddles 2 3x 4x 1 1 2 2 4 Parts Replacement and Cleaning 188 ...
Страница 211: ...2 Remove the HDD Unit 1 3 Hooks 2 1 Screw 3 1x 2 2 3 4 Parts Replacement and Cleaning 189 ...
Страница 249: ...2 3 1x 4 Parts Replacement and Cleaning 227 ...
Страница 293: ...Adjustment 5 Pickup Feed System 272 Document Exposure System 275 Actions after Replacement 277 ...
Страница 306: ...Troubleshooting 6 Initial Check 285 Test Print 286 Troubleshooting Items 291 Debug Log 304 ...
Страница 345: ...Error Jam Alarm 7 Outline 324 Error Code 328 Error Code FAX 466 Alarm Code 469 Jam Code 517 ...
Страница 949: ...COPIER Service mode for printer COUNTER Counter mode LIFE DF PR PD 1 For R D 8 Service Mode 927 ...
Страница 1010: ...Super G3 FAX Board AZ1 1147 Super G3 2nd Line Fax Board AU1 1154 Cassette Heater Unit 41 1167 9 Installation 988 ...
Страница 1018: ...5 Remove the cushioning material from the copyboard section Model without DADF Model with DADF 9 Installation 996 ...
Страница 1025: ...4 NOTE The removed cover will be used in step 6 5 2x 2x 6 NOTE Use the cover removed in step 4 9 Installation 1003 ...
Страница 1029: ...1 2 2x 3 4 NOTE The removed CR BOX Upper Unit will be used in step 14 9 Installation 1007 ...
Страница 1033: ...13 NOTE Usethe Base Small Cover removed in step 5 14 NOTE Use the CR BOX Upper Unit removed in step 4 15 9 Installation 1011 ...
Страница 1050: ...Installation Procedure Installing the Equipment 1 2 3 9 Installation 1028 ...
Страница 1052: ...8 Turn ON the main power switch 9 Installation 1030 ...
Страница 1055: ...3 4 CAUTION Be sure that the Inner 2 way Tray Support Member is installed properly 9 Installation 1033 ...
Страница 1063: ...2 2x 1x 3 1x 1x 1x 4 1x 1x NOTE The removed screw will be used in step 5 9 Installation 1041 ...
Страница 1065: ...6 CAUTION Be careful not to trap the cable when mounting the cover 1x 7 2x 9 Installation 1043 ...
Страница 1075: ... In the case of the Reversal DADF 1 2 3 NOTE The removed part will be used in step 8 9 Installation 1053 ...
Страница 1088: ...4 6x 5 4x 6 7 NOTE Do not close the Wire Saddle 1x 8 9 Installation 1066 ...
Страница 1090: ...12 NOTE Be sure to adjust the number of cushions according to the thickness of the Card Reader 13 9 Installation 1068 ...
Страница 1091: ...14 15 16 17 2x 18 9 Installation 1069 ...
Страница 1103: ...3 CAUTION Install the CC VI Cable in the direction shown in the figure 2x 1x Installing the Covers 1 1x 9 Installation 1081 ...
Страница 1104: ...2 2x 3 Connect the power plug to the outlet 4 Turn ON the power switch 9 Installation 1082 ...
Страница 1111: ...5 CAUTION To avoid damage do not pull the Utility Tray too much 6 2x 2x TP M4x8 Black 9 Installation 1089 ...
Страница 1112: ...When Installing the USB Keyboard 1 9 Installation 1090 ...
Страница 1114: ...Installation Procedure Removing the Covers 1 2x 2 1x 3 2x 9 Installation 1092 ...
Страница 1115: ... Installing the Removable HDD Kit 1 2 3x 4x 9 Installation 1093 ...
Страница 1119: ...11 12 1x 13 NOTE Use the screw removed in step 3 1x 9 Installation 1097 ...
Страница 1120: ...14 3x 4x Installing the Covers 1 2 2x 3 1x 9 Installation 1098 ...
Страница 1123: ...Installation Procedure Removing the Covers 1 2x 2 1x 3 2x 9 Installation 1101 ...
Страница 1124: ... Installing the 2 5inch 1TB HDD 1 3x 4x 2 1x NOTE The removed screws will be used in step 7 9 Installation 1102 ...
Страница 1127: ...8 3x 4x Installing the Covers 1 2x 2 1x 9 Installation 1105 ...
Страница 1134: ...2 On the screen shown below press Change and then Detailed Settings 3 9 Installation 1112 ...
Страница 1140: ...Installation procedure Remove the Control Panel 1 2 2x 3 4 2x 5 2x 9 Installation 1118 ...
Страница 1141: ...6 2x 7 4x 8 3x 9 10 9 Installation 1119 ...
Страница 1142: ...11 12 6x 13 2x 14 9 Installation 1120 ...
Страница 1143: ... Installing the NFC Kit 1 2 2x 3 1x TP M3x4 4 1x 9 Installation 1121 ...
Страница 1144: ... Installing the Control Panel 1 2 2x 3 6x 4 9 Installation 1122 ...
Страница 1145: ...5 6 3x 7 4x 8 2x 9 10 2x 9 Installation 1123 ...
Страница 1146: ...11 2x 12 13 2x 14 9 Installation 1124 ...
Страница 1154: ...14 4x Installing the Relay PCB 1 1x 1x TP M3x6 1x 2 1x 1x 9 Installation 1132 ...
Страница 1155: ...3 4 2x 3x 5 4x 6 9 Installation 1133 ...
Страница 1162: ... Installing the Relay PCB 1 1x 1x TP M3x6 1x 2 1x 1x 9 Installation 1140 ...
Страница 1163: ...3 4 2x 3x 5 4x 9 Installation 1141 ...
Страница 1166: ...1 CAUTION Do not insert the screwdriver into the hole when removing the cover 2 3 2x 9 Installation 1144 ...
Страница 1167: ...4 1x 5 CAUTION Be sure to install the Dehumidification switch in the correction direction 1x 9 Installation 1145 ...
Страница 1172: ... Installing the Covers 1 1x 2 NOTE Store the removed Face Cover in the Tray Guide in step 5 3 2x 4 9 Installation 1150 ...
Страница 1180: ...6 1x 7 8 5x M3x6 9 Installation 1158 ...
Страница 1192: ...5 CAUTION Be sure to release the lock and then disconnect the FCC Connector 1x 6 7 9 Installation 1170 ...
Страница 1193: ... Installing the Cassette Heater 1 2 3 In the case of Host machine TP Round End M3x6 1x 9 Installation 1171 ...
Страница 1200: ...2 3 2x 4 1x 9 Installation 1178 ...
Страница 1201: ...5 CAUTION Be sure to install the switch in the correction direction 1x 6 2x 9 Installation 1179 ...
Страница 1202: ...7 8 9 Connect the power plug of the host machine to the outlet 10 Turn ON the main power switch 9 Installation 1180 ...