1) According to the location where the symptom occurred, check disconnection of the connector for an appropriate cassette from
among a) to d).
If no connector is disconnected, check other factors (disconnection of cable and unit etc.)
a) If "Load paper" is displayed to the cassette 1, check J1222 of the cassette 1 size switch.
b) If "Load paper" is displayed to the cassette 2, check J1221 of the cassette 2 size switch A.
c) If "Load paper" is displayed to the cassette 3
c-1) Check J1136 of the cassette 3 size switch A.
c-2) Check J603 of Deck driver PCB.
d) If "Load paper" is displayed to the cassette 4, check J1139 of the cassette 4 size switch A.
2) Start the main body and, please confirm that a phenomenon does not occur.
66
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...