Copier Color | iR-ADV C3330/C3325/C3320 Series |
Uneven density at 15.5mm intervals
[Symptom]
When a paper of 106gsm or more is used, uneven density at 15.5mm intervals [a] may occur on a high density image.
The arrow [b] indicates the direction of feeding.
[Cause]
If the developing cylinder [a] inside the developing unit is minutely eccentric, the distance between the developing cylinder and
the drum [b] gyrates and the above mentioned symptom occurs.
[Service work]
1) Go to Service mode (Lv2) > Mode List > COPIER > Option > IMG-DEV > and change the setting value of "ADJ-VPPN" to "1".
The range of setting is from "-1" to "4" ("0" by default).
Increment the developing AC bias by 100V by changing the parameter.
[CAUTION] Increment of the parameter may generate image fogging, ring marks and uneven density at 15.5mm on a halftone
image.
2) Output the image having shown the symptom, and check that the symptom does not occur.
If the improvement of the symptom is not good enough, inclement the parameter of the step 1) by "1" at a time up to when it
reaches "+4" and see how the result is.
3) Output the image having shown the symptom, and check that the symptom does not occur.
If the symptom does not improve, revert the parameter of the step 1) to its original value and check other causes.
40
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...