[Reference]
- There will be no harm to adjust 2 colors (Y+M, Y+C or M+C) or 3 colors (Y+M+C) at a time.
- The symptom will be almost improved within the adjustment range between "0" to "-70",.
8) Output the test sheet "CA-1" in A3 full color and confirm the symptom does not occur any more.
If the symptom does not improve, then revert all the parameters to "0" and try to check again the steps from 2) to 7).
If the symptom persists even after the above, then revert all the parameters to "0" and check other causes.
9
) Go to Settings/Registration > Adjustment/Maintenance > Adjust Image Quality > Auto Adjust Gradation > and execute Full Adjust
following the UI screen.
10
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...