5) Reassemble the parts in reverse order from the step 3).
6) Take a set of copy with 3 sheets of original placed in the ADF original tray, and check that the above mentioned symptom does
not occur.
[Service parts]
No.
Part Number
Description
1
Old
FC9-4971-010
LEVER, EMPTY SENSOR
New
FC9-4971-020
LEVER, EMPTY SENSOR
2
Old
FM1-C226-000
PAPER PICK-UP COVER ASS'Y
New
FM1-C226-010
PAPER PICK-UP COVER ASS'Y
[Countermeasure cut-in serial numbers in factory]
iR-ADV C3300 Series
Model
Serial No.
iR-ADV C3330 230V
QTZ03390
iR-ADV C3325 230V
QUB01732
iR-ADV C3320 230V
QUC04197
iR-ADV C3330 CN 220V
QUE01095
iR-ADV C3325 CN 220V
QUF01219
iR-ADV C3320 CN 220V
QUG03584
iR-ADV C3320L CN 220V
QUH03045
iR-ADV C3330I EUR 230V
QTF10607
iR-ADV C3325I EUR 230V
QTS18651
iR-ADV C3320I EUR 230V
QTT17453
iR-ADV C3320 EUR 230V
QTU01206
iR-ADV C3330 IND 230V
RJS00748
iR-ADV C3325 IND 230V
RJU00689
iR-ADV C3320 IND 230V
RJV02620
iR-ADV C3330 KR 220V
QUJ01006
iR-ADV C33125K KR 220V
QUK05331
iR-ADV C3320 KR 220V
QUL03000
iR-ADV C3330I LTN 230V
RJQ00722
iR-ADV C3325I LTN 230V
RJR00758
iR-ADV C3330 TW 120V
QUM00519
iR-ADV C3325 TW 120V
QUN00509
iR-ADV C3320 TW 120V
QUP00581
iR-ADV C3330I 120V
QTV07510
iR-ADV C3325I 120V
QTW10392
iR-ADV C3330I 120V G
QTX00560
iR-ADV C3330 CN 220V G
TYT00569
iR-ADV C3325 CN 220V G
TYV00593
136
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...