1) If waste toner has overflowed onto the Intermediate Guide, this waste toner can be fed into the Waste Toner Container by
operating the Waste Toner Feed Motor (M17) (COPIER > FUNCTION > PART-CHK > MTR = 14).
2) Fully open the Right Door.
3) Remove the ITB Unit.
4) Remove the Front Door.
5) Remove the Toner Bottle.
6) Remove the Drum Unit (Y).
7) Remove the Developing Unit (Y).
8) Remove the Left Cover (Upper).
9) Remove the First Delivery Tray.
10) Remove the Toner Bottle Mount.
11) Remove the Control Panel Lower Cover [1].
- 2 Screws [2]
- 2 Claws [3]
12) Release the 2 links [1] of the Bottle Motor.
[CAUTION] When installing the links of the Bottle Motor, be sure to pinch the Lock Arm [1].
109
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...