Copier Color | iR-ADV C3330/C3325/C3320 Series |
The marks caused by friction on the second side of the paper of
duplex printing
[Symptom]
In case of duplex printing, the marks caused by friction of image [a] / [b] on the front /rear side edge of the second side of paper
may appear.
The arrow [c] indicates the direction of feeding.
This symptom is likely to occur with a paper has been left in a high humidity environment.
[Cause]
If the paper is curled largely after the fixing for the first side, the behavior of the second side of the paper goes unstable between
the secondary transfer assembly and the fixing nip, and the paper can be twisted or forming an inverted curl while being fed.
If the unfixed portion of the twisted/inverted curled sheet friction on the fixing film, the aforementioned symptom occurs.
[Service work]
[Reference]
Improving a state of preservation of paper may be effective in resolving a trouble in some cases.
Explain to a customer that unused or remaining paper should be stored by being covered with wrapping paper in a place avoiding
direct sunlight.
1) If the device is used in a high humidity environment, turn the dehumidifier switch ON.
The cassette heater is turned on and prevents the paper from absorbing moisture.
2) Identify the paper type with which the symptom occurs and change the setting value of the appropriate location from Service
Mode > Mode List > COPIER > "Option" to "-1".
-Plain paper 1 (64 to 75 gsm): CUSTOM > Change "TMP-TBL".
-Plain paper 2 (76 to 90 gsm): IMG-FIX > Change "TMP-TBL7".
38
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...