Warning Message
Copier Color | iR-ADV C3330/C3325/C3320 Series |
"Replace Toner Cartridge" message is displayed on the initial
installation or after replacing the toner cartridge
[Symptom]
"Replace Toner Cartridge" message may be displayed on the initial installation or after replacing the toner cartridge.
[Cause]
When toner is difficult to come out of the toner cartridge after inserting the cartridge, the message "Replace Toner Cartridge" is
displayed on UI screen.
If the main power is turned off while the machine is in the said condition, as toner is not supplied enough in the developing unit,
the data of no toner remains in the machine.
If the main power is turned on after that, the backed up data of no toner is used in the machine and the machine determines that
the toner cartridge is empty.
As a result, the "Shake Toner Cartridge" message is not displayed on the UI screen but "Replace Toner Cartridge" instead.
[Service work]
1) Open the front cover, then pull out the toner cartridge.
2) Shake the toner cartridge vertically about 10 times, keeping the white part upward.
3) Insert the toner cartridge and close the front door.
[Caution] When the "Shake Toner Cartridge" message appears again, the prior notification of toner cartridge delivery is delivered
via UGW.
120
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...