[Service work]
When the above symptom occurs, prepare one new type large roller holder (FL0-2752-010) and two small roller holders
(FL0-2751-010), and replace the old ones by following the procedure below. In addition, when installing the new type parts, the
paper feed sheet is no longer needed. Be sure to remove and discard it.
< Procedure >
1) Open the ADF and remove the lower base cover [1].
- 2 screws
2) Remove the 2 leaf springs [1].
- 2 screws
3) Remove the paper feed roller unit [1].
[Note] The part is not secured. Be sure not to make it fall or not to lose it.
141