2) Select a paper source of the paper type that needs to undergo the correction, and press "OK". According to the message
appearing on the screen, output a test print and scan it, and perform Full Adjust.
[Reference] The following shows recommended paper for Japan, USA, and Europe.
-JPN : CS680/68g [Nippon Paper]
-USA : Canon Multipurpose 20lb/75g [Domtar]
-EUR : Oce Red Label 80/80g [Mondi Business Paper]
3) Output the image having shown the symptom, and check that the symptom does not occur. If the symptom no longer occurs,
the work is completed.
4) Identify the paper type with which the symptom occurs and change the setting value of the appropriate location from Service
Mode (Lv2) > Mode List > COPIER > Adjust > "EXP-LED" to "100".
- If the symptom occurs with paper of 105gsm or less, change the 4 parameters: PR-EXP-Y/ PR-EXP-M/ PR-EXP-C/ PR-EXP-
K.
- If the symptom occurs with paper of 106gsm or more, change the 4 parameters: PR-EXPY2/ PR-EXPM2/ PR-EXPC2/ PR-
EXPK2.
The range of setting is from "-100" to "+100" ("0" by default).
Raising the level of the parameters increases the light intensity of pre- exposure LED and evens out the residual potentials on
the drum.
[Caution] Change of the parameter may induce streaks in horizontal direction [a] on a halftone image caused by the drum. The
arrow [b] indicates the direction of feeding.
5) Output the image having shown the symptom, and check that the symptom does not occur.
18
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...