B-1
Appendix B.
Cables, Pinouts, LED
Function, and Jumper
B.1 CS I/O
The CS I/O cable is a 9-pin, straight-through cable with all 9 pins connected. The
supplied SC12 cable (part number #16675) is recommended.
Table B-1. CS I/O Pinout
Pin
Datalogger (DB9 Female)
Function
Peripheral (DB9 Male)
Function
1
5 VDC
N/C
2
SIGNAL GND
SIGNAL GND
3
RING
RING
4
RXD
TXD
5
ME
ME
6
SDE
SDE
7
CLK/HS
CLK/HS
8
12 VDC
N/C
9
TXD
RXD
B.2 RS-232
A DB9 female to DB9 male cable (such as Campbell Scientific part number
#10873) is used to connect the NL200/201’s RS-232 port to the datalogger’s RS-
232 port. The supplied SC12 cable can also be used. A DB9 female null modem
cable (such as Campbell Scientific part number #13657) is used to connect the
NL200/201’s RS-232 port to a PC’s RS-232 port. The RS-232 cable should be
kept short when using high baud rates.
Table B-2. RS-232 Pinout
Pin
Datalogger (DCE, DB9 Female)
Function
Peripheral (DTE, DB9 Male)
Function
1
DCD
DCD
2
TXD
RXD
3
RXD
TXD
4
DTR
DTR
5
SIGNAL GND
SIGNAL GND
6
DSR
DSR
7
CTS
RTS
8
RTS
CTS
9
RING
RING
B.3 Ethernet
The Ethernet 10Base-T/100Base-TX cable should be a Category 5 or better
twisted pair cable (such as Campbell Scientific part number #13658). The two
Содержание NL200
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ...iv...
Страница 36: ...NL200 201 Network Link Interface 26...
Страница 42: ...Appendix B Cables Pinouts LED Function and Jumper B 4...
Страница 54: ......
Страница 60: ...Appendix D NL200 201 Driver Installation Instructions D 6...
Страница 62: ...Appendix E Sending a New OS to the NL200 201 E 2...
Страница 63: ......