User Manual
17
On the RS-232 tab:
o
Set Configuration to “TCP Serial Server”.
o
Set Baud Rate to baud rate of attached device.
o
Make note of the Serial Server Port. (The default RS-232 Serial Server
Port is 6784. Typically, it is not necessary to change this entry from its
default.)
CS I/O Serial Server
Connect to the NL200/201 in DevConfig (see Section 6,
Configuring the
NL200/201
).
On the NL200 tab:
o
Set Bridge Mode to “disable”.
On the CS I/O tab:
o
Set Configuration to “TCP Serial Server”.
o
Set SDC address. (Note that if multiple peripherals are connected to a
datalogger’s CS I/O port, each must have a unique SDC address.)
o
Make note of the Serial Server Port. (The default CS I/O Serial Server
Port is 6783. Typically, it is not necessary to change this entry from its
default.)
7.3.3
LoggerNet Setup
The next step is to run LoggerNet and configure it to connect to the datalogger via
the Ethernet port. (See example in Figure 7-3 below.)
In LoggerNet’s Setup Screen, press Add Root and choose “IPPort”. Input the
NL200/201’s IP address and port number. The IP address and port number
are input on the same line separated by a colon.
Add a PakBus Port.
Add the datalogger and input the PakBus address of the datalogger.
Press Apply to save the changes.
You can verify your settings are correct by selecting the datalogger in the
Network Map, selecting the Clock tab, and pressing Check Clocks. If your
settings are correct, you should see the current clock of your server and
datalogger.
Содержание NL200
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ...iv...
Страница 36: ...NL200 201 Network Link Interface 26...
Страница 42: ...Appendix B Cables Pinouts LED Function and Jumper B 4...
Страница 54: ......
Страница 60: ...Appendix D NL200 201 Driver Installation Instructions D 6...
Страница 62: ...Appendix E Sending a New OS to the NL200 201 E 2...
Страница 63: ......