Open DevConfig. Select the device type of the datalogger (CR800, CR1000,
or CR3000), the appropriate Communication Port, and the baud rate. Press
Connect to connect to the datalogger.
If using a static IP address, select the CS I/O IP tab and input the IP address,
subnet mask, and IP gateway for the correct CS I/O Interface. The default for
the NL200/201 is CS I/O IP Interface #1 (SDC3). DNS server settings are
shared by all active IP interfaces and can be entered on the TCP/IP tab. These
values can be provided by your network administrator. If using DHCP, leave
the CS I/O IP address settings as 0.0.0.0. You will find the information
acquired by DHCP in the TCP/IP info box on the TCP/IP tab.
Press Apply to save the changes and then close DevConfig.
The NL200/201 must be connected to the datalogger before
configuring the datalogger with DevConfig. If it is not connected,
the TCP/IP settings will not be displayed.
7.2.4
LoggerNet Setup
The next step is to run LoggerNet and configure it to connect to the datalogger via
the Ethernet port. (See example in Figure 7-2 below.)
In LoggerNet’s Setup Screen, press Add Root and choose “IPPort”. Input the
datalogger’s IP address and port number. The IP address and port number are
input on the same line separated by a colon. (The datalogger’s default port
number is 6785. It can be changed using DevConfig or by modifying its value
in the Status Table. Unless firewall issues exist, the port number does not
need to be changed from its default value.)
Add a PakBus Port.
Add the datalogger (CR800, CR1000, or CR3000) and input the PakBus
address of the datalogger.
You can verify that your settings are correct by selecting the datalogger in the
Network Map, selecting the Clock tab, and pressing Check Clocks. If your
settings are correct, you should see the current clock of your server and
datalogger.
NOTE
Содержание NL200
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ...iv...
Страница 36: ...NL200 201 Network Link Interface 26...
Страница 42: ...Appendix B Cables Pinouts LED Function and Jumper B 4...
Страница 54: ......
Страница 60: ...Appendix D NL200 201 Driver Installation Instructions D 6...
Страница 62: ...Appendix E Sending a New OS to the NL200 201 E 2...
Страница 63: ......