NL200/201 Network Link Interface
16
Figure 7-2. Bridge mode LoggerNet setup
7.2.5
Connect
You are now ready to connect to your datalogger using the LoggerNet Connect
Screen.
7.3
Serial Server
The NL200/201 can tunnel RS-232 and CS I/O serial communications over
Ethernet. Any packet sent to the configured Ethernet IP port will have the IP layer
removed, and the serial data is then directed to the serial connection.
7.3.1
Physical Setup
Using the supplied serial cable, connect the NL200/201’s CS I/O port or RS-232
port to the datalogger’s CS I/O or RS-232 port, respectively. The NL201 will be
powered if connected via CS I/O. Alternatively, power the NL200 or NL201
through the barrel-connector jack located on the edge of the device. Connect the
NL200/201 to your network using an Ethernet cable, attaching one end of the
cable to the NL200/201’s Ethernet port and the other end to your network. Ensure
that the device is powered up by inspecting the Power LED.
7.3.2
Configuring the NL200/201
RS-232 Serial Server
Connect to the NL200/201 in DevConfig (see Section 6,
Configuring the
NL200/201
).
On the NL200 tab:
o
Set Bridge Mode to “disable”.