Keyword
Information and Location
PortConfig
Provides information on the configuration settings (input, output, SDM,
SDI-12, COM port) for C terminals in numeric order of terminals. Default =
Input. Updates when the port configuration changes.
l
String data type
l
Read only
PortStatus
States of C terminals configured for control. On/high (True) or off/low
(False). Array elements in numeric order of C terminals. Default = False.
Updates when state changes.
l
Boolean data type
ProcessTime
Processing time (μs) of the last scan. Time is measured from the end of the
EndScan instruction (after the measurement event is set) to the beginning
of the EndScan (before the wait for the measurement event begins) for the
subsequent scan. Calculated on-the-fly. Updated at the conclusion of
scan processing, prior to waiting for the next scan.
l
Numeric data type
l
Read only
ProgErrors
Number of compile or runtime errors for the running program. Updated
after compile.
l
Numeric data type
l
Read only
ProgName
Name of current (running) program; updates at startup.
l
String data type
l
Read only
ProgSignature
Signature of the running CRBasic program including comments. Does not
change with operating-system changes. Updates after compiling the
program.
l
Numeric data type
l
Read only
9. Tips and troubleshooting
134
Содержание CR1000X
Страница 1: ...Revision 02 21 2019 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...Appendix A Glossary 176 Appendix B Index 214 Table of Contents viii ...
Страница 20: ...l Smart sensors o SDI 12 o RS 232 o Modbus o DNP3 o TCP IP o RS 485 1 Data acquisition system components 4 ...
Страница 192: ......
Страница 237: ...wiring panel 5 Appendix B Index 220 ...