datalogger, connect to it in Device Configuration Utility, click the Backup menu and select
Backup Datalogger.
Table 5-1: Powerup.ini commands
Command
Action
Details
1
Run always,
preserve data
Copies a program file to a drive and sets the program to both
Run Now and Run on Power Up. Data on a memory card from
the previously running program will be preserved if table
structures have not changed.
2
Run on
power up
Copies a program file to a drive and sets the program to Run
Always unless command 6 or 14 is used to set a separate Run
Now program.
5
Format
Formats a drive.
6
Run now,
preserve data
Copies a program file to a drive and sets the program to Run
Now. Data on a memory card from the previously running
program will be preserved if table structures have not
changed.
7
Copy
support files
Copies a file, such as an Include or program support file, to
the specified drive.
9
Load OS
(File= .obj)
Loads an
.obj
file to the CPU drive and then loads the
.obj
file as the new datalogger operating system.
13
Run always,
erase data
Copies a program to a drive and sets the program to both Run
Now and Run on Power Up. Data on a memory card from the
previously running program will be erased.
14
Run now,
erase data
Copies a program to a drive and sets the program to Run Now.
Data on a memory card from the previously running program
will be erased.
15
Move file
Moves a file, such as an Include or program support file, to the
specified drive.
5.6.2 Example powerup.ini files
Comments can be added to the file by preceding them with a single-quote character ('). All text
after the comment mark on the same line is ignored.
5. Data memory
44
Содержание CR1000X
Страница 1: ...Revision 02 21 2019 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...Appendix A Glossary 176 Appendix B Index 214 Table of Contents viii ...
Страница 20: ...l Smart sensors o SDI 12 o RS 232 o Modbus o DNP3 o TCP IP o RS 485 1 Data acquisition system components 4 ...
Страница 192: ......
Страница 237: ...wiring panel 5 Appendix B Index 220 ...