Keyword
Information and Location
Neighbo
u
rs
This
setting
specifies,
for
a
given
port,
the
explicit
list
of
PakBus
node
addresses
that
the
datalogger
will
accept
as
neighbo
u
rs.
If
the
list
is
empty
(the
default
value)
any
node
will
be
accepted
as
a
neighbo
u
r.
This
setting
will
not
affect
the
acceptance
of
a
neighbo
u
r
if
that
neighbor's
address
is
greater
than
3999.
l
String data type
Where to find:
l
Settings
Editor
tab
in
Device
Configuration
Utility:
Com
Ports
Settings
|
Neighbo
u
rs
Allowed
NTPServer
This setting specifies an NTP Server to be queried (once per day) to
adjust the datalogger clock. This setting uses the
setting. If
UTC Offset setting is not set, it is assumed to be 0.
l
String data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: Advanced |
NTP Server
PakBusAddress
This
setting
specifies
the
PakBus
address
for
this
device.
Valid
values
are
in
the
range
1
to
4094.
The
value
for
this
setting
must
be
chosen
such
that
the
address
of
the
device
will
be
unique
in
the
scope
of
the
datalogger
network.
Duplication
of
PakBus
addresses
can
lead
to
failures
and
unpredictable
behavior
in
the
PakBus
network.
When
a
device
has
an
allowed
neighbo
u
r
list
for
a
port,
any
device
that
has
an
address
greater
than
or
equal
to
4000
will
be
allowed
to
connect
to
that
device
regardless
of
the
allowed
neighbo
u
r
list.
l
Numeric data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: Datalogger |
PakBus Address
9. Tips and troubleshooting
150
Содержание CR1000X
Страница 1: ...Revision 02 21 2019 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...Appendix A Glossary 176 Appendix B Index 214 Table of Contents viii ...
Страница 20: ...l Smart sensors o SDI 12 o RS 232 o Modbus o DNP3 o TCP IP o RS 485 1 Data acquisition system components 4 ...
Страница 192: ......
Страница 237: ...wiring panel 5 Appendix B Index 220 ...