Keyword
Information and Location
MaxProcTime
Maximum time (μs) required to run through processing for the current
scan. Value is reset when the scan exits. Enter 0 to reset. Updated at the
conclusion of scan processing, prior to waiting for the next scan.
l
Numeric data type
MaxSystemProcTime
Maximum time (μs) required to process the auto (background) calibration,
which runs in a hidden slow-sequence type scan. Displays 0 until a
background calibration runs. Enter 0 to reset.
l
Numeric data type
l
Read only
MeasureOps
Reports the number of task-sequencer opcodes required to do all
measurements. Calculated at compile time. Includes operation codes for
calibration (compile time), auto (background) calibration (system), and
slow sequences. Assumes all measurement instructions run each scan.
Updated after compile and before running.
l
Numeric data type
l
Read only
MeasureTime
Reports the time (μs) needed to make measurements in the current scan.
Calculated at compile time. Includes integration and settling time. In
pipeline mode, processing occurs concurrent with this time so the sum of
MeasureTime and ProcessTime is not equal to the required scan time.
Assumes all measurement instructions will run each scan. Updated when a
main scan begins.
l
Numeric data type
l
Read only
MemoryFree
Unallocated final storage memory on the CPU (bytes). All free memory
may not be available for data tables. As memory is allocated and freed,
holes of unallocated memory, which are unusable for final-storage
memory, may be created. Updated after compile completes.
l
Numeric data type
l
Read only
9. Tips and troubleshooting
132
Содержание CR1000X
Страница 1: ...Revision 02 21 2019 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...Appendix A Glossary 176 Appendix B Index 214 Table of Contents viii ...
Страница 20: ...l Smart sensors o SDI 12 o RS 232 o Modbus o DNP3 o TCP IP o RS 485 1 Data acquisition system components 4 ...
Страница 192: ......
Страница 237: ...wiring panel 5 Appendix B Index 220 ...