ConfigCom
x
Specifies the configuration for a datalogger control port as it relates to
serial communications. It is significant only when the associated port
baud rate setting is set to something other than Disabled. This setting
denotes the physical layer properties used for communications. It does
not indicate the port's current configuration as it relates to standard or
inverted logic. Options include:
l
RS-232: Configures the port as RS-232 with standard voltage
levels.
l
TTL: The port is configured to use TTL, 0 to 5V voltage levels. By
default, the port will use inverted logic levels. Use the SerialOpen
CRBasic command to configure this port for standard TTL logic
levels.
l
LVTTL: The port is configured to use Low Voltage TTL (LVTTL), 0 to
3.3V voltage levels. By default, the port will use inverted logic
levels. Use the SerialOpen() CRBasic command to configure this
port for standard TTL logic levels.
l
RS-485 Half-Duplex PakBus: The port is configured as RS-485
half-duplex (two wire) and uses the PakBus/MDROP protocol. This
allows reliable PakBus peer-to-peer networking of multiple
devices including the MD485 and NL100 using the RS-485
interface.
l
RS-485 Half-Duplex Transparent: The port is configured as RS-485
half-duplex (two wire). This setting is most commonly used when
communicating with other non-PakBus RS-485 devices. Use this
setting when communicating with devices such as Modbus RTUs
or third-party serial sensors with RS-485 interfaces.
l
RS-485 Full Duplex Transparent: The port is configured as RS-485
full-duplex (four wire). In this configuration, four adjacent control
ports will be required.
Where to find:
l
Settings Editor tab in Device Configuration Utility: Com Ports
Settings | COMx | Configuration
9. Tips and troubleshooting
140
Содержание CR1000X
Страница 1: ...Revision 02 21 2019 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...Appendix A Glossary 176 Appendix B Index 214 Table of Contents viii ...
Страница 20: ...l Smart sensors o SDI 12 o RS 232 o Modbus o DNP3 o TCP IP o RS 485 1 Data acquisition system components 4 ...
Страница 192: ......
Страница 237: ...wiring panel 5 Appendix B Index 220 ...