![Campbell CR1000X Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/campbell/cr1000x/cr1000x_product-manual_489087114.webp)
Table 7-1: Example power use for a network of SDI-12 probes
Time into
Measurement
Processes
Command
All
Probes
Awake
Time
Out
Expires
Probe
1 (mA)
Probe
2 (mA)
Probe
3 (mA)
Probe
4 (mA)
Total
(mA)
Sleep
0.25
0.25
0.25
0.25
1
1
1M!
Yes
120
66
66
66
318
2–14
120
66
66
66
318
15
Yes
120
66
66
66
318
16
1D0!
Yes
66
66
66
66
264
17-29
66
66
66
66
264
30
Yes
66
66
66
66
264