Appendix
Ⅱ
Instruction of System Level Mistake
BECS-528 Computerized Embroidery Machine's Manual
109
Appendix
Ⅱ
Instruction of System Level Mistake
At present, the 528 model may give 2 system-level warning at start-up: the one is “Data
Abort”; the other is “Start Abort”. During the process of running the data program, the system
may give the warning “Data Abort” instead of the “StartAbort”. These two warnings can be
seen at the upper left corner of the screen like
“
”
&
“
”
. We will give the
explanation of these two errors:
1.
“Data Abort”
This means the CPU occurs the internal and unrecoverable mistake. At present, what we
can do is just to restart the computer. And has no other solutions.
2.
“StartAbort”
This phenomenon may have two causes, one is not updating the data program, the other is the
chip on mother board is damaged. Therefore, the solution of it is to re-update the data program.
If the problem still exists after the update, please replace the mother board.