Product description

Use

The COBRA BC vacuum pumps are designed for use in the field of mi-
croelectronics and similar industries.

They can be used to suck gases and gas mixtures.

WARNING

When using toxic, inflammable and/ or explosive gases, make sure
that the system corresponds in design to applicable local and na-
tional safety regulations and that all applicable safety measures are
followed.
All product-specific safety regulations must be observed.

Solid particles must not get into the vacuum pump. Procedural errors
can result in the pump sucking in a certain quantity of liquid. If the
pump has sucked in liquid, a short drying time is necessary at the end
of the procedure.

The allowed maximum inlet gas temperature depends on the inlet pres-
sure and the type of gas: the lower the inlet pressure (Pa), the higher
the drawn gas temperature (TGas) can be.

The following indicative values for air can be considered:

– Pa > 50 mbar, TGas < 80°C
– Pa < 50 mbar, TGas < 200°C

The vacuum pump is intended for use in a potentially non-explosive
environment.

As far as temperature is concerned, the pump is suitable for evacuation
of a 300 liters tank. The pump is not suitable for continuous duty at a
pressure more or equal than 150 mbar. Caution, the operating cycle of
150 mbar must not exceed more than 5 min. For other applications,
contact your Busch representative.

The vacuum pump is tight down to ultimate pressure.

Operating principle

COMBI

The COBRA BC 0600 F pumps are a combination of a screw vacuum
pump NW 0100 E (DP) and a Roots vacuum pump WY 0700 C (MB)

The COBRA BC 0600 F vacuum pumps are COBRA NW screw vacuum
pumps with cooling water and nitrogen circuits.

Product description

BC 0600 F

Page 6

0870767449 (En)

DP

 

7

4

 

2     5 

3

 

8

 

1

 

6

 

4

 

MB  

1

Inlet

2

Outlet

3

Oil

4

Cooling water

5

Barrier gas

6

Motor klixon DP

7

Intake medium

8

Screw rotors

9

Roots lobe

Nitrogen inlet

 

MB

 

DP

 

Process gas inlet

 

Process gas outlet

 

TSA

 

DGF

 

PRV

 

PSA

 

TS2

 

DGR2

 

CWM

 

PS 

    

OSG4

 

MOT1

 

OSG1

 

OSG3

 

DGR1

 

MOT2

 

TS3

 

Cooling water 
inlet

 

CWR

 

Cooling water 
outlet

 

TSA Temperature sensor PT100 (DP)
TS1 Temperature switch Motor (MB)
TS2 Temperature switch Motor (DP)
DGF Nitrogen flow meter, dilution gas
PRV Nitrogen pressure reducer
PS

Inlet pressure switch

PSA Outlet pressure sensor
OSG 1 Oil level indicator (DP)
OSG 3 Oil level indicator (MB)
OSG 4 Oil level indicator (MB)
MOT 1 Motor (DP)
MOT 2 Motor (MB)
CWR Cooling water regulating valve
DGR 1 Regulating valve, dilution gas
DGR 2 Regulating valve, dilution gas
CWM Cooling water flow meter

Содержание COBRA BC 0600 F

Страница 1: ...bi Screw and Roots Vacuum Pumps COBRA BC 0600 F Standard version Busch Manufacturing Korea Ltd 189 51 Soicheon ro Majang myun Icheon si Gyunggi do 467 813 Republic of Korea 0870767449 181024 Original...

Страница 2: ...mp on off 15 First start up of the system 15 Switching the system off 16 Maintenance 16 Maintenance program 16 Weekly 16 Monthly 17 Yearly 17 Every 16 000 hours of operation at the latest after 4 year...

Страница 3: ...ons NC Nitrogen connections CP PLC box EB Eyebolts CPC PLC connection ES Emergency stop button EMO MB On off switch Main circuit breaker CAO Extracting ventilator RF Ventilator EC Electrical connectio...

Страница 4: ...BC 0600 F Page 4 0870767449 En TSA DGF DGR2 DGR1 PSA PS MOT2 MOT1 CWM CWR OSG1 OSG4 OFP TS1...

Страница 5: ...BC 0600 F 0870767449 En Page 5 MB PWS CT CB MB On off switch Main circuit breaker PWS DC Power Supply CT Current Transducer CB Circuit breaker...

Страница 6: ...not suitable for continuous duty at a pressure more or equal than 150 mbar Caution the operating cycle of 150 mbar must not exceed more than 5 min For other applications contact your Busch representat...

Страница 7: ...ted in the middle hole is preset at 2 l min and can be adjusted with valve DGR 1 depending on the appli cation Nitrogen flow injected in the hole on cylinder endplate side is preset at 10 l min and ca...

Страница 8: ...be observed when installing the pump in potentially explosive en vironments The maintenance instructions must be observed and respected It is vital that these installation and maintenance instruction...

Страница 9: ...d nitrogen quick connections inlet first then outlet l Put the label or warning board Maintenance processing on or next to the pump Emergency off circuit description l The Emergency off circuit may be...

Страница 10: ...vacuum pump incl drive motor If any accesso ries that could upset the balance of the vacuum pump are installed or if the vacuum pump is delivered without drive motor it is necessary to add a belt or r...

Страница 11: ...verpressure 2 5 bar relative Water hardness 5 dGH NOTE 1 german degree 1 dGH 1 78 french degree 1 25 e english degree 17 9 mg kg CaCO3 american hardness Minimum flow rate 3 4 l min for the standard ve...

Страница 12: ...ump is connected to the vacuum line l Make sure that the nominal diameter of the exhaust line is at least equal to the diameter of the exhaust flange of the vacuum pump to prevent a drop in the perfor...

Страница 13: ...following regulations IEC 364 or CENELEC HD 384 or DIN VDE 0100 IEC Report 664 or DIN VDE 0110 VBG 4 or corresponding national regulations on accident preven tion Power wiring connection Power wiring...

Страница 14: ...device u Close the shut off device If the intake line is not equipped with a shut off device u Place a rubber plate on the intake flange l Let the vacuum pump run for a few minutes l Stop the vacuum p...

Страница 15: ...insulated vacuum pump CAUTION The COBRA BC 0600 F vacuum pumps could be delivered without oil without cooling water Operation without oil will result in damage to the vacuum pump The vacuum pump must...

Страница 16: ...ed off and that it cannot be switched on again acciden tally Follow the shutdown procedure in the section Lock Out Tag Out procedure stop the pump with the LCD control press on STOP button during 10s...

Страница 17: ...emergency stop button l Switch on the water and nitrogen quick connections outlet first then inlet l Make sure that the Necessary installation instructions are follo wed l Start the pump with the LCD...

Страница 18: ...them Always clean away this swarf when removing the drain plugs Because of wear and tear of the seals it is recommended to replace the drain plugs whenever the oil is changed Filling in new oil l Prep...

Страница 19: ...edure described in the chapter Installation and Commissioning Dismantling and Disposal of the vacuum pump DANGER In case the vacuum pump has conveyed gases that have been contaminated with harmful for...

Страница 20: ...hazardous pump conditions which could cause personal injury Oil quantity The quantity of oil specified in the following table is of informative nature only Check the oil level with the help of the var...

Страница 21: ...mate pressure 50 Hz 60 Hz kW kW 1 9 2 1 Nominal motor speed DP 50 Hz DP 60 Hz min 1 3000 3600 Nominal motor speed MB 50 Hz MB 60 Hz min 1 3000 3600 Noise level EN ISO 2151 dB A 62 Ambient temperature...

Страница 22: ......

Страница 23: ...equipment and following the standards Standard Title of the standard EN ISO 12100 2010 Safety of machinery Basic concepts general principles of design EN ISO 13857 2008 Safety of machinery Safety dis...

Страница 24: ...Majang myun Icheon si Gyunggi do 467 813 Republic of Korea Phone 82 31 645 2700 Fax 82 31 631 2898 e mail busch busch co kr Malaysia Busch Malaysia Sdn Bhd 4 6 Jalan Taboh 33 22 Seksyen 33 Shah Alam T...

Отзывы: