CAUTION
When the intake lines have been connected, make sure that the sys-
tem does not leak. Leakages of dangerous substances must be pre-
vented!
l
Make sure that the intake lines are equipped with a shut-off device
upstream of the intake flange so that the flow of sucked gas can
be stopped
l
Make sure that the intake lines do not exercise any force on the in-
take flange. Mount bellows if necessary
l
The inlet flange has the following dimension:
–
DN 63 ISO-K
In the case of long intake lines, the line cross-section should be larger
than the intake flange to prevent a drop in the performance of the va-
cuum pump. If you have any doubts, contact your Busch representa-
tive.
Discharge connection
CAUTION
Do not put hands into the outlet aperture.
Risk of body damage!
The following instructions for connection to the discharge only apply if
the sucked gas is discharged by the vacuum pump into a suitable envi-
ronment.
l
Make sure that the protection that was attached to prevent pene-
tration of particles during transport has been removed before the
vacuum pump is connected to the vacuum line
l
Make sure that the nominal diameter of the exhaust line is at least
equal to the diameter of the exhaust flange of the vacuum pump
to prevent a drop in the performance of the vacuum pump in the
case of a smaller cross-section
l
Make sure that the vacuum pump is connected with leakproof lines
CAUTION
When the discharge lines have been connected, make sure that the
system does not leak. Leakages of dangerous substances must be
prevented!
l
Make sure that the discharge line is mounted in such a way that
condensate cannot penetrate into the pump (siphon trap, gradient)
l
Make sure that no shut-off devices are mounted in the discharge
line
l
Make sure that the discharge lines do not exercise any force on the
discharge flange. Mount bellows if necessary
l
The discharge flange has the following dimension:
–
DN 40 ISO KF
In the case of long discharge lines the line cross-section should be lar-
ger than the discharge flange to prevent a drop in the performance of
the vacuum pump. If you have any doubts, contact your Busch repre-
sentative.
Installation and Commissioning
BC 0600 F
Page 12
0870767449 (En)
Tool Interface
LCD 1
LCD 2
Prog
USB
Cust.Nwk
EDH
PID
P
o
w
e
r
R
U
N
N2 REG.
POWER CONNECTOR
Dimensional drawing BC 0600 F
Содержание COBRA BC 0600 F
Страница 4: ...BC 0600 F Page 4 0870767449 En TSA DGF DGR2 DGR1 PSA PS MOT2 MOT1 CWM CWR OSG1 OSG4 OFP TS1...
Страница 22: ......