background image

Information over the lubricants

Oil

Busch YLC 250 B, Art. No. 0831 000 054 (0,5 l

@

1 kg)

Quantity BC 0600 F

:

WY 0700 C-MB: 1,4 l

NW 0100 E-DP: 0,12 l

Replacement: After 16'000 h (see Maintenance program)

Technical data sheet: Please refer to chapter "Oil type/ Quantity".

Decommissioning procedure

When the product arrives at the end of the lifetime, it is necessary to
proceed to the decontamination of the vacuum pump

WARNING

Any disassembly of the vacuum pump should only be carried out by
staff trained for this purpose. Before disassembly, the user of the
vacuum pump should complete a form or “Declaration about
absence of danger” which indicates any dangers and corresponding
actions.
Without this form duly completed and signed by a legally responsi-
ble person, the pump should not be disassembled.

l

Proceed to disassembly of the vacuum pump. Please make sure to
wear a personal protective equipment (PPE) prior to any interven-
tion on the vacuum pump. Some residue may remain inside.

l

Proceed to decommissioning of the different parts according to the
current local and national laws

Transport

The COBRA BC vacuum pumps are tested and checked in our factory
before careful packing. Check the packaging for transport damage
when the goods arrive. The pump can withstand temperatures
between -25°C and +55°C during transport.

Transport in packed state

Packed on a pallet, the vacuum pump can be moved with a hand
forklift truck.

Transport in unpacked state

The vacuum pump is fastened to the pallet with fixing pins:

u

Unscrew the fastening nuts underneath the pallet.

CAUTION

Do not work, walk or stand under suspended loads.

CAUTION

Please check out the weight of the vacuum pump before lifting it up
(see "Technical Data").

Use adequate lifting gear for this.

NOTE

: The eyebolts are fitted more or less at equal distance from the

centre of gravity of the vacuum pump incl. drive motor. If any accesso-
ries that could upset the balance of the vacuum pump, are installed, or
if the vacuum pump is delivered without drive motor, it is necessary to
add a belt or rope at a suitable point when lifting the pump.

l

Attach lifting gear securely to the eyebolt or eyebolts

l

Use lifting gear with a crane hook equipped with safety latch.

l

Lift the vacuum pump

In case the vacuum pump was bolted to a pallet with fixing bolts:
Unscrew the fixing bolts in the base frame.

CAUTION

In case of a vacuum pump filled with oil, make sure that by lifting
the inclination angle of the vacuum pump do not exceed 5° from
the horizontal . In case of too high inclination (>5°), risk of oil leak
within the work area.

Make sure before every transport using the appropriate lifting mean
that the inclination of the vacuum pump is less than 5°.

The packaging material must be disposed of in accordance with local
and national regulations.

This handbook is contained in the delivery package.

Storage

Temporary storage

l

Make sure that the intake and exhaust flanges are closed (put on
the protective caps included in the delivery package of the vacuum
pump)

l

Store the vacuum pump

if possible, the vacuum pump should be stored in its original pac-
kaging,

indoors,

dry,

in a dust-free and vibration-free room

Removal of the pump

Before starting a vacuum pump that has been stored outside the buil-
ding for a while, the vacuum pump must be moved to a room with
ambient temperature, where it should rest for a day.

Preservation

If the vacuum pump will be exposed to unfavourable ambient condi-
tions (for example, aggressive environment, frequent temperature
changes), begin immediately with preservation work on the vacuum
pump.
In the case of favourable ambient conditions, perform preservation
work on the vacuum pump if a storage period of more than three
months are planned.

l

Make sure that all openings are hermetically sealed; use adhesive
tape to fasten loose parts (seal rings, flat seals, etc.).

Transport

BC 0600 F

Page 10

0870767449 (En)

Содержание COBRA BC 0600 F

Страница 1: ...bi Screw and Roots Vacuum Pumps COBRA BC 0600 F Standard version Busch Manufacturing Korea Ltd 189 51 Soicheon ro Majang myun Icheon si Gyunggi do 467 813 Republic of Korea 0870767449 181024 Original...

Страница 2: ...mp on off 15 First start up of the system 15 Switching the system off 16 Maintenance 16 Maintenance program 16 Weekly 16 Monthly 17 Yearly 17 Every 16 000 hours of operation at the latest after 4 year...

Страница 3: ...ons NC Nitrogen connections CP PLC box EB Eyebolts CPC PLC connection ES Emergency stop button EMO MB On off switch Main circuit breaker CAO Extracting ventilator RF Ventilator EC Electrical connectio...

Страница 4: ...BC 0600 F Page 4 0870767449 En TSA DGF DGR2 DGR1 PSA PS MOT2 MOT1 CWM CWR OSG1 OSG4 OFP TS1...

Страница 5: ...BC 0600 F 0870767449 En Page 5 MB PWS CT CB MB On off switch Main circuit breaker PWS DC Power Supply CT Current Transducer CB Circuit breaker...

Страница 6: ...not suitable for continuous duty at a pressure more or equal than 150 mbar Caution the operating cycle of 150 mbar must not exceed more than 5 min For other applications contact your Busch representat...

Страница 7: ...ted in the middle hole is preset at 2 l min and can be adjusted with valve DGR 1 depending on the appli cation Nitrogen flow injected in the hole on cylinder endplate side is preset at 10 l min and ca...

Страница 8: ...be observed when installing the pump in potentially explosive en vironments The maintenance instructions must be observed and respected It is vital that these installation and maintenance instruction...

Страница 9: ...d nitrogen quick connections inlet first then outlet l Put the label or warning board Maintenance processing on or next to the pump Emergency off circuit description l The Emergency off circuit may be...

Страница 10: ...vacuum pump incl drive motor If any accesso ries that could upset the balance of the vacuum pump are installed or if the vacuum pump is delivered without drive motor it is necessary to add a belt or r...

Страница 11: ...verpressure 2 5 bar relative Water hardness 5 dGH NOTE 1 german degree 1 dGH 1 78 french degree 1 25 e english degree 17 9 mg kg CaCO3 american hardness Minimum flow rate 3 4 l min for the standard ve...

Страница 12: ...ump is connected to the vacuum line l Make sure that the nominal diameter of the exhaust line is at least equal to the diameter of the exhaust flange of the vacuum pump to prevent a drop in the perfor...

Страница 13: ...following regulations IEC 364 or CENELEC HD 384 or DIN VDE 0100 IEC Report 664 or DIN VDE 0110 VBG 4 or corresponding national regulations on accident preven tion Power wiring connection Power wiring...

Страница 14: ...device u Close the shut off device If the intake line is not equipped with a shut off device u Place a rubber plate on the intake flange l Let the vacuum pump run for a few minutes l Stop the vacuum p...

Страница 15: ...insulated vacuum pump CAUTION The COBRA BC 0600 F vacuum pumps could be delivered without oil without cooling water Operation without oil will result in damage to the vacuum pump The vacuum pump must...

Страница 16: ...ed off and that it cannot be switched on again acciden tally Follow the shutdown procedure in the section Lock Out Tag Out procedure stop the pump with the LCD control press on STOP button during 10s...

Страница 17: ...emergency stop button l Switch on the water and nitrogen quick connections outlet first then inlet l Make sure that the Necessary installation instructions are follo wed l Start the pump with the LCD...

Страница 18: ...them Always clean away this swarf when removing the drain plugs Because of wear and tear of the seals it is recommended to replace the drain plugs whenever the oil is changed Filling in new oil l Prep...

Страница 19: ...edure described in the chapter Installation and Commissioning Dismantling and Disposal of the vacuum pump DANGER In case the vacuum pump has conveyed gases that have been contaminated with harmful for...

Страница 20: ...hazardous pump conditions which could cause personal injury Oil quantity The quantity of oil specified in the following table is of informative nature only Check the oil level with the help of the var...

Страница 21: ...mate pressure 50 Hz 60 Hz kW kW 1 9 2 1 Nominal motor speed DP 50 Hz DP 60 Hz min 1 3000 3600 Nominal motor speed MB 50 Hz MB 60 Hz min 1 3000 3600 Noise level EN ISO 2151 dB A 62 Ambient temperature...

Страница 22: ......

Страница 23: ...equipment and following the standards Standard Title of the standard EN ISO 12100 2010 Safety of machinery Basic concepts general principles of design EN ISO 13857 2008 Safety of machinery Safety dis...

Страница 24: ...Majang myun Icheon si Gyunggi do 467 813 Republic of Korea Phone 82 31 645 2700 Fax 82 31 631 2898 e mail busch busch co kr Malaysia Busch Malaysia Sdn Bhd 4 6 Jalan Taboh 33 22 Seksyen 33 Shah Alam T...

Отзывы: