Principle of DP vacuum pumps

The COBRA NW screw vacuum pumps work by the principle of spiral
pumps. Two parallel screws (8) rotate in opposite directions in the
pump body. Entering gases are trapped between the flights of the
screws and the pump body. The gases are conveyed by the rotation of
the screws to the exhaust, where they are discharged.

The COBRA NW screw vacuum pumps are driven by water-cooled mo-
tors.

Principle of MB vacuum pumps

The Roots vacuum pumps operate according to the approved principle
of the Roots type machine. Operation is both simple and effective.
Two lobes (9) with identical profiles rotate in opposition directions wi-
thin a casing. As they rotate, gas is drawn into the space between each
lobe and the casing where it is trapped and by the rotation pushed out
into the discharge. This action is repeated twice for each revolution of
each lobe and therefore four times for each revolution of the drive
shaft. There is no mechanical contact between lobes and cylinder. So
no oil lubrication is required.
The drive motor of roots pump is a water cooled canned motor.

Gas flow checks

A pressure sensor PSA at the discharge monitors the discharge pres-
sure. If the pressure reaches more than the limit value (alarm, preset at
the factory: 0.2 bar), the purge cycle starts.

Oil circuit

Since the complete operating principle works without contact, no oil
circuit is needed in the work area.

Cooling

The vacuum pump is cooled by

a direct cooling water circuit in the motors and the DP and MB
transmission casing . The flow regulating valve CWR of cooling
water is preset on 2 l/min at the factory.

a direct cooling water circuit in the rear bearing (for exceptionally
cool running in option).

NOTE

: The COBRA BC 0600 F vacuum pumps are principally dispat-

ched without oil already in the vacuum pump but, without cooling wa-
ter. Before vacuum pump first startup, control the oil level and the
cooling liquid level. In the event of absence of one or the other of
these lubricants, please carry out the filling (please refer to the various
chapters of filling). Do not forget to connect the cooling water supply
before the first startup. Operation without these coolants can result in
damage to the vacuum pump.

Nitrogen system

The nitrogen system can be used in a number of different ways :

nitrogen is used as dilution gas. It is injected inside the cylinder on two
different places. Nitrogen flow injected in the middle hole is preset at 2
l/ min and can be adjusted with valve DGR 1, depending on the appli-
cation. Nitrogen flow injected in the hole on cylinder endplate side is
preset at 10 l/ min and can be adjusted with valve DGR 2, depending
on the application. When flow is too low a warning then an alarm signal
is generated by flowmeter DGF to the PLC. Status of the pump depends
on the alarm function set by user (factory setting : None, pump conti-
nues running with an alarm). Dilution improves the screws functioning,
especially when sucking corrosive gases.

nitrogen is used as sealing gas. The nitrogen is injected between
the transmission and the process gas to achieve good closeness.
The Nitrogen flow used for the sealing is set by two chips (

f

). With

a pressure of 1,5 bar, the flow is around 8-10 l/min.

nitrogen is used as purge gas. The purge eliminates traces of gases
remaining in the vacuum pump. The vacuum pump purge cycle is
programmed in the control and starts, either after a STOP opera-
tion or after an alarm function.
For a correct purge execution, the shut-off valve at the inlet flange
must be closed. The purge cycle lasts about 30 min. (Program-
mable time in the basic parameters).

Optional functions/ Use of available
accessories

A pressure sensor (PSA) mounted at the exhaust , controls the over-
pressure at the exhaust. If overpressure is above 0,3 bar, pressure
sensor gives a warning then an alarm signal. Status of the pump de-
pends on the alarm function set by user (factory setting : None, pump
continues running with an alarm).

A temperature sensor PT100 (TSA) mounted on the cylinder, measures
the temperature inside the cylinder (DP).

A silencer or sound absorber (accessory) at the exhaust reduces the
noise of the pump and collects any condensate.

A leak-protection non-return valve (optional) at the exhaust traps the
condensate in the pump when the pump is switched off.

The LCD controller processes the data of the sensors as follows:

PSA: exhaust pressure

TSA: temperature inside the cylinder DP

MOT 1 and MOT 2: DP and MB current and speed

DGF: nitrogen flow rate, dilution

CWM: cooling water flow rate in motors/ transmission

See "Installation and Maintenance Instructions, Busch PLC and Busch
LCD (No. 0870758077)".

On/ Off switch

The vacuum pump is delivered with a circuit breaker. The function
start/ stop can be done in Local by using the LCD controller or in Re-
mote by the production machine.

Versions

Further vacuum pump descriptions state the nominal displacement and
the design level.

Example: BC 0600 F
BC = standard version
0600 = 600 m

3

/h

F = Design

BC 0600 F

Product description

0870767449 (En)

Page 7

Содержание COBRA BC 0600 F

Страница 1: ...bi Screw and Roots Vacuum Pumps COBRA BC 0600 F Standard version Busch Manufacturing Korea Ltd 189 51 Soicheon ro Majang myun Icheon si Gyunggi do 467 813 Republic of Korea 0870767449 181024 Original...

Страница 2: ...mp on off 15 First start up of the system 15 Switching the system off 16 Maintenance 16 Maintenance program 16 Weekly 16 Monthly 17 Yearly 17 Every 16 000 hours of operation at the latest after 4 year...

Страница 3: ...ons NC Nitrogen connections CP PLC box EB Eyebolts CPC PLC connection ES Emergency stop button EMO MB On off switch Main circuit breaker CAO Extracting ventilator RF Ventilator EC Electrical connectio...

Страница 4: ...BC 0600 F Page 4 0870767449 En TSA DGF DGR2 DGR1 PSA PS MOT2 MOT1 CWM CWR OSG1 OSG4 OFP TS1...

Страница 5: ...BC 0600 F 0870767449 En Page 5 MB PWS CT CB MB On off switch Main circuit breaker PWS DC Power Supply CT Current Transducer CB Circuit breaker...

Страница 6: ...not suitable for continuous duty at a pressure more or equal than 150 mbar Caution the operating cycle of 150 mbar must not exceed more than 5 min For other applications contact your Busch representat...

Страница 7: ...ted in the middle hole is preset at 2 l min and can be adjusted with valve DGR 1 depending on the appli cation Nitrogen flow injected in the hole on cylinder endplate side is preset at 10 l min and ca...

Страница 8: ...be observed when installing the pump in potentially explosive en vironments The maintenance instructions must be observed and respected It is vital that these installation and maintenance instruction...

Страница 9: ...d nitrogen quick connections inlet first then outlet l Put the label or warning board Maintenance processing on or next to the pump Emergency off circuit description l The Emergency off circuit may be...

Страница 10: ...vacuum pump incl drive motor If any accesso ries that could upset the balance of the vacuum pump are installed or if the vacuum pump is delivered without drive motor it is necessary to add a belt or r...

Страница 11: ...verpressure 2 5 bar relative Water hardness 5 dGH NOTE 1 german degree 1 dGH 1 78 french degree 1 25 e english degree 17 9 mg kg CaCO3 american hardness Minimum flow rate 3 4 l min for the standard ve...

Страница 12: ...ump is connected to the vacuum line l Make sure that the nominal diameter of the exhaust line is at least equal to the diameter of the exhaust flange of the vacuum pump to prevent a drop in the perfor...

Страница 13: ...following regulations IEC 364 or CENELEC HD 384 or DIN VDE 0100 IEC Report 664 or DIN VDE 0110 VBG 4 or corresponding national regulations on accident preven tion Power wiring connection Power wiring...

Страница 14: ...device u Close the shut off device If the intake line is not equipped with a shut off device u Place a rubber plate on the intake flange l Let the vacuum pump run for a few minutes l Stop the vacuum p...

Страница 15: ...insulated vacuum pump CAUTION The COBRA BC 0600 F vacuum pumps could be delivered without oil without cooling water Operation without oil will result in damage to the vacuum pump The vacuum pump must...

Страница 16: ...ed off and that it cannot be switched on again acciden tally Follow the shutdown procedure in the section Lock Out Tag Out procedure stop the pump with the LCD control press on STOP button during 10s...

Страница 17: ...emergency stop button l Switch on the water and nitrogen quick connections outlet first then inlet l Make sure that the Necessary installation instructions are follo wed l Start the pump with the LCD...

Страница 18: ...them Always clean away this swarf when removing the drain plugs Because of wear and tear of the seals it is recommended to replace the drain plugs whenever the oil is changed Filling in new oil l Prep...

Страница 19: ...edure described in the chapter Installation and Commissioning Dismantling and Disposal of the vacuum pump DANGER In case the vacuum pump has conveyed gases that have been contaminated with harmful for...

Страница 20: ...hazardous pump conditions which could cause personal injury Oil quantity The quantity of oil specified in the following table is of informative nature only Check the oil level with the help of the var...

Страница 21: ...mate pressure 50 Hz 60 Hz kW kW 1 9 2 1 Nominal motor speed DP 50 Hz DP 60 Hz min 1 3000 3600 Nominal motor speed MB 50 Hz MB 60 Hz min 1 3000 3600 Noise level EN ISO 2151 dB A 62 Ambient temperature...

Страница 22: ......

Страница 23: ...equipment and following the standards Standard Title of the standard EN ISO 12100 2010 Safety of machinery Basic concepts general principles of design EN ISO 13857 2008 Safety of machinery Safety dis...

Страница 24: ...Majang myun Icheon si Gyunggi do 467 813 Republic of Korea Phone 82 31 645 2700 Fax 82 31 631 2898 e mail busch busch co kr Malaysia Busch Malaysia Sdn Bhd 4 6 Jalan Taboh 33 22 Seksyen 33 Shah Alam T...

Отзывы: