![Burnham 5006B Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/burnham/5006b/5006b_installation-and-operation-manual_2832904092.webp)
92
FLUID POWER GAS
TRAINS - USA
(See Page 91 for “LO-HI-LO” Natural Gas Diaphragm
Type V
alves)
PAR
T NO.
ITEM
BOILER SIZE
5006B - 5008B
5009B - 5014B
5015B
5016B
5017B - 5026B
Fluid Power Gas V
alve
81660010
1” - Honeywell V5055B1002
1
---
1
1
---
8166001
1
1¼” - Honeywell V5055B1010
---
1
---
1
1
Actuators for Fluid Power V
alves
81660012
“Lo-Hi-Of
f” Honeywell V4055A1007 - 5026B Sec. Opening
Time - 120V 60HZ
81660013
“Lo-Hi-Lo” Honeywell V4062A1008 - 5026B Sec. Opening
Time - 120V 60HZ
81660014
“Modulating” Honeywell V9055A1055 - 5026B Sec. Opening
Time - 120V 60HZ
Solenoid Gas V
alve
81660088
1” - ITT
Gen. K3A562
3
---
3
3
---
81660086
1¼” - ITT
Gen. K3A772
---
3
---
3
3
Nat. Gas Regulator - Std. Cad Plate Spring 3.0” x 6.0” WC
8226006
Maxitrol R
V-61 1” x 1”
4A
---
4A
4A
---
8226012
Maxitrol R
V-81 1¼” x 1¼”
---
4A
---
4A
4A
LP
Gas Regulator HO1 Blue Spring 5.5” to 12.0” WC
822601
1
Maxitrol R
V-61 1” x 1”
4B
---
3B
3B
---
8226012
Maxitrol R
V-81 1¼” x 1¼”
---
4B
---
4B
4B
822614
Leak Limiter - Maxitrol #12A04 (included w/ R
V-61)
5
---
5
5
---
8226010
Leak Limiter - Maxitrol #12A34 (included w/ R
V-81)
---
5
---
5
5
Manual Shutof
f V
alve
822615
ConBraCo 50-GB5-01A
1” x 1”
6
---
6
---
---
8226161
ConBraCo 50-GB6-01A
1¼” x 1¼”
---
6
---
6
6
822645
Pilot V
alve
7
7
7
7
7
Sec
Ti
ON V
i - R
eP
A
iR P
ARTS (continued)
Содержание 5006B
Страница 10: ...10 Fig 6 ARRANGEMENT OF SECTIONS AND CANOPY S SECTION III INSTALLATION INSTRUCTIONS continued...
Страница 22: ...22 Fig 22 SECURING OF CANOPY DRAFTHOOD SECTION III INSTALLATION INSTRUCTIONS continued...
Страница 23: ...23 Fig 23 CANOPY DRAFTHOOD MOUNTING DIAGRAM SECTION III INSTALLATION INSTRUCTIONS continued...
Страница 29: ...29 Fig 28 MOUNTING ELEVATIONS OF M M 150 AND A 67M FLOAT LWCO SECTION III INSTALLATION INSTRUCTIONS continued...
Страница 51: ...51 Fig 46 wiring diagram 5006B THRU 5014B SECTION BOILERS OP CONTROL SYSTEM SECTION IV OPERATION continued...
Страница 53: ...53 Fig 47 wiring diagram 5015B THRU 5026B SECION BOILERS OP CONTROL SYSTEM SECTION IV OPERATION continued...
Страница 55: ...55 Fig 48 wiring diagram 5006B THRU 5014B SECTion BOILERS EP CONTROL SYSTEM SECTION IV OPERATION continued...
Страница 56: ...56 Fig 49 wiring diagram 5015B THRU 5026B SECTION BOILERS EP CONTROL SYSTEM SECTION IV OPERATION continued...
Страница 68: ...68 Fig 58 PILOT LOCATIONS SECTION V SERVICE continued...
Страница 72: ...72 SERVICE RECORD DATE SERVICE PERFORMED...
Страница 74: ...74 Fig 64 BASE PARTS 5006B Thru 5014B SECTION VI REPAIR PARTS continued...
Страница 76: ...76 Fig 65 BASE PARTS 5015B thru 5026B SECTION VI REPAIR PARTS continued...
Страница 78: ...78 Fig 66 INTEGRAL CANOPY DRAFTHOODS SECTIONS SECTION VI REPAIR PARTS continued...
Страница 82: ...82 Fig 67 JACKETS SECTION VI REPAIR PARTS continued...
Страница 102: ...102 Control assembly and mounting bracket OP EP CONTROL SYSTEMS SECTION VI REPAIR PARTS continued...
Страница 111: ...111 SERVICE RECORD DATE SERVICE PERFORMED...
Страница 112: ...112...