3.
CONDENSATION
Following a cold start, condensation (sweating) may
occur in a gas fired boiler to such an extent that it
cONTROL VARiATiONS
NATURAL GAS
MODeL NO.
cONTROL
SYSTeM
TYPe OF
PiLOT
GAS VALVeS
OPTiONAL MAiN
VALVeS
ReFeReNce
PAGe
PiLOT
MAiN
5006B-5009B (USA)
EI
Elec. Ign.
(1) 7000DERHC-S7C
(B)
45
5010B-5026B (USA)
5006B-5026B (CANADA)
EI
Elec. Ign.
(1) H91WG-6
(2) V88A
(B)**
46-48
5006B-5026B
(USA & CANADA)
OP
Standing Q179D
(1) L62GB-3C
(2) V88A
(A), (B)
51 & 53
5008B-5026B
(USA & CANADA)
EP
Elec. Ign. Q179C
(1) H91WA-4
(2) V88A
(A), (B)*
55 & 56
5006B-5013B (CANADA)
24V
Standing
(1) L62GB-3C
(2) V88A
(A), (B)
59
5015B-5024B (CANADA)
24V
Standing
(1) 62GB-3C
(2) V88A
(A), (B)
60
LP GAS
MODeL NO.
cONTROL
SYSTeM
TYPe OF
PiLOT
GAS VALVeS
OPTiONAL MAiN
VALVeS
ReFeReNce
PAGe
PiLOT
MAiN
5006B-5009B (USA)
EI
Elec. Ign.
(1) 7000DERHC-S7C
45
5006B-5026B (USA)
OP
Standing Q179D
(1) L62GB-3C
(2) V88A
(A)
51 & 53
5006B-5026B (CANADA)
OP
Standing Q179D
(1) L62GB-3C
(2) V88A
---
51 & 53
(A) -- (1) Honeywell V5055B Motorized Gas Valve with V4055A/V4062A/V9055A Actuator and (1) ITT K3A
Solenoid Valve (120V)
(B) -- (1) Honeywell V8944B Combination Gas Valve and (1) ITT K3A Solenoid Valve (24V)
* -- To be used with (1) H91WA-4 Pilot Valve (120V)
** -- To be used with (1) H91WG-6 Pilot Valve (24V)
NOTE:
1. For Steam or Water
2. For 24V Thermostat Application - Wire S861OM Relay in Place of Operating Control Set Thermostat Heat
Anticipator at 0.4 Amp. See Pages 45, 46 and 47.
3. All Battery Operated Thermostats
must
be Electrically Isolated From the Primary Circuit by an Isolating Relay.
appears that the boiler is leaking. This condensation
can be expected to stop after the boiler is hot.
SecTiON iV - OPeRATiON (continued)
Содержание 5006B
Страница 10: ...10 Fig 6 ARRANGEMENT OF SECTIONS AND CANOPY S SECTION III INSTALLATION INSTRUCTIONS continued...
Страница 22: ...22 Fig 22 SECURING OF CANOPY DRAFTHOOD SECTION III INSTALLATION INSTRUCTIONS continued...
Страница 23: ...23 Fig 23 CANOPY DRAFTHOOD MOUNTING DIAGRAM SECTION III INSTALLATION INSTRUCTIONS continued...
Страница 29: ...29 Fig 28 MOUNTING ELEVATIONS OF M M 150 AND A 67M FLOAT LWCO SECTION III INSTALLATION INSTRUCTIONS continued...
Страница 51: ...51 Fig 46 wiring diagram 5006B THRU 5014B SECTION BOILERS OP CONTROL SYSTEM SECTION IV OPERATION continued...
Страница 53: ...53 Fig 47 wiring diagram 5015B THRU 5026B SECION BOILERS OP CONTROL SYSTEM SECTION IV OPERATION continued...
Страница 55: ...55 Fig 48 wiring diagram 5006B THRU 5014B SECTion BOILERS EP CONTROL SYSTEM SECTION IV OPERATION continued...
Страница 56: ...56 Fig 49 wiring diagram 5015B THRU 5026B SECTION BOILERS EP CONTROL SYSTEM SECTION IV OPERATION continued...
Страница 68: ...68 Fig 58 PILOT LOCATIONS SECTION V SERVICE continued...
Страница 72: ...72 SERVICE RECORD DATE SERVICE PERFORMED...
Страница 74: ...74 Fig 64 BASE PARTS 5006B Thru 5014B SECTION VI REPAIR PARTS continued...
Страница 76: ...76 Fig 65 BASE PARTS 5015B thru 5026B SECTION VI REPAIR PARTS continued...
Страница 78: ...78 Fig 66 INTEGRAL CANOPY DRAFTHOODS SECTIONS SECTION VI REPAIR PARTS continued...
Страница 82: ...82 Fig 67 JACKETS SECTION VI REPAIR PARTS continued...
Страница 102: ...102 Control assembly and mounting bracket OP EP CONTROL SYSTEMS SECTION VI REPAIR PARTS continued...
Страница 111: ...111 SERVICE RECORD DATE SERVICE PERFORMED...
Страница 112: ...112...